Dometic RM 7651 L Refrigerator User Manual


 
8
Gas operation
The refrigerator should only be operated using liquid gas
(propane, butane). Do not use town gas or natural gas.
If the refrigerator is operated during travel using gas, the precautions
stipulated by the legislation in the respective country must be taken (in
conformity with the European standard EN 732).
Operating the refrigerator with gas is not permitted during travel in
France and Australia.
As a basic rule, operation using gas is prohibited in petrol stations.
1. Open the valve of the gas cylinder
2. Open the shut-off valve to the gas supply.
The ignition process is activated automatically, accompanied by a ticking sound
approx. 30 sec. Upon successful ignition, the display LED (C) Gas lights yellow.
The refrigerator is in function. Use rotary switch (B) to regulate the temperature in the
main refrigerator compartment.
AUTO-operation
RM7XX5 L - models are equipped with an AUTO-MATIC function.
Explanations:
Upon switching on, the electronics automatically select one of the three
possible energy types: 230V - 12V - liquid gas. The control electronics
automatically ensure that the refrigerator is supplied with the optimum
source of energy in each respective case.
Priority 1.) Solar (12V DC)
2.) 230V AC
3.) 12V DC
4.) Liquid gas
The selected energy is displayed by the corresponding LED (i.e. 230V)
.
A
1. Set energy selector switch (A) to gas
2. Set rotary switch (B) to MAX postion.
C
5.2.3
5.2.4
B. Automatic Energy Selection (RM 76x5 L)
1. Set energy selection switch (A) to position
AUTO .
The LED "AUTO" illuminates
.
Manual operation is possible at any time.