EdgeStar HZB- 12 Ice Maker User Manual


 
USING YOUR ICE MAKER
1. Select the size of the ice cube by pressing the “Select” button. If the room temperature is
lower than 60°F, it is best to select the small or medium ice size, otherwise the ice cubes
might stick together.
2. Open the cover, remove the ice basket and pour water into tank.
Keep water level below the level mark.
3. Press “Power” on the control panel to begin the ice making cycle.
4. The ice making cycle lasts 6 to 15 minutes, depending on the size of the ice cubes
selected.
5. While the ice maker is on, verify the water level periodically. If the water level is too low,
the ice maker will stop automatically, and the “Water” indicator will turn on.
Press the “Power” button, fill the unit with water, and press “Power” again.
Allow the refrigerant inside the compressor at least 3 minutes to settle before restarting.
6. The ice maker automatically stops working when the ice basket is full.
7. Change the water in the water reservoir every 24 hours to ensure a reasonable hygiene
level.
If the ice maker will not be used for an extended period of time, you should drain the water
from the reservoir.
PROBLEM POSSIBLE CAUSE SOLUTION
The “Water” indicator is
on.
Low water level.
Stop the ice maker, fill it with
water, and then restart it.
The “Ice” indicator is on.
The ice basket is full. Remove ice from the ice basket.
The “Water” and “Ice”
indicators are both
flashing.
The ice shovel cannot
move.
Check if the ice is blocking the
ice shovel, otherwise, consult a
qualified technician.
The ice cycle is too long.
Stop the ice maker, and restart it
when the ice blocks melt. Select
the small ice button.
The ice cubes stick
together.
The water temperature in
the inner tank is too low.
Change the water in the inner
tank. The ideal water temperature
is 45°-90°F.
The ambient temperature
or the water temperature is
too high.
Please run the ice maker in
temperatures below 90°F and/or
pour colder water into tank.
Refrigerant liquid leakage. Consult a qualified technician.
The ice making cycle
seems normal but no ice is
produced.
A pipe in the cooling
system is blocked.
Consult a qualified technician.
TROUBLESHOOTING