Supply voltage 230 V, 1N, 50/60 230 V, 1N, 50/60 230 V, 1N, 50/60 230 V, 1N, 50/60
Net weight - kg. 145 145 145 145
auxiliary 0.3 0.3 0.3 0.3
gas 35 35 35 35
cooking chamber 20 20 20 20
electric 0.3 0.3 0.3 0.3
auxiliary 0.3 0.3 0.3 0.3
boiler 20 20 20 20
Power - kW
height 736 736 736 736
depth 715 715 715 715
width 460 460 460 460
Internal dimensions - mm
height 1080 1080 1080 1080
depth 845 845 845 845
width 895 895 895 895
External dimensions - mm
N° of programs 100 100
Semi-automatic cleaning cycle
Meat probe
Multi Point Probe
Two-speed fan
Low temp steaming
Regeneration
Cook&hold
Humidity control
Convection/steaming
Steaming
Convection
combi 250 250 250 250
steam 100 100 100 100
air-convection 300 300 300 300
Cooking cycles - °C
Runners pitch - mm 65 65 65 65
Shelf capacity 10 10 10 10
Type of grids 1/1 Gastronorm 1/1 Gastronorm 1/1 Gastronorm 1/1 Gastronorm
Functional level Programmable;
Top
Programmable;
Top
Medium Medium
Natural Gas LPG Natural Gas LPG
Power supply Gas Gas Gas Gas
TECHNICAL DATA
AOS101GAGQ
260662
AOS101GADQ
260672
AOS101GBGQ
260663
AOS101GBDQ
260673
Manual injection of water in the cell.
Built-in retractable hand shower.
Steam generator water draining
with an automatic scale diagnosis
system.
HACCP management as standard:
it allows recording the cooking
programme according to H.A.C.C.P.
standard (Hazard Analysis and Critical
Control Points). According to the
system requested it will be possible
to record the cooking data with the
oven’s printer (optional) or directly in
a Personal Computer.
PERFORMANCE
• Air-o-clima [Patented] (just for
"version A” models): controls and
displays the exact (single degree of
accuracy) humidity degree of the
oven atmosphere in hot air, mixed
and regeneration cycles. Air-o-clima
measures physically the real humidity
level inside the cooking cell and acts
consequently according to the set
value. With hot air cycles, air-o-clima
also manages to exhaust the excess
humidity generated from the food.
Air-o-flow: blows fresh air from
outside through the new fan, which
pulls the air in from the backside of
the oven, after it is pre-heated and
therefore without compromising the
evenness of the cooking process.
Multi-sensor food probe: 6 sensors,
½ ºC accuracy.
CONSTRUCTION
• Stainless steel 304 throughout, with
seamless joints in the cooking cell.
Height adjustable legs.
Double thermoglazed door with
two-stage opening to let out the
steam for maximum security and four
holding positions allowing easier
loading and unloading manoeuvres.
Halogen lighting in the cooking cell.
Spray unit included as standard.
Access to main components from
the front panel.
Platinum probe in the boiler to
detect the presence of scale build-up.
IPX5 water protection.
Air-o-steam ovens meet and VDE
safety requirements.Installation
diagram:
D = overflow drain pipe
U = air intake
P = fumes outlet