Electrolux 210621236-11052010 Refrigerator User Manual


 
Defrosting of the freezer
The freezer compartment of this model, on the other hand, is a "no frost" type. This
means that there is no buildup of frost when it is in operation, neither on the internal
walls nor on the foods.
The absence of frost is due to the continuous circulation of cold air inside the compart-
ment, driven by an automatically controlled fan.
WHAT TO DO IF…
CAUTION!
Before troubleshooting, disconnect the power supply.
Only a qualified electrician or competent person must do the troubleshooting that is not
in this manual.
There are some sounds during normal use (compressor, refrigerant circulation).
Problem Possible cause Solution
The appliance is noisy.
The appliance is not supported
properly.
Check if the appliance stands sta-
ble (all the four feet should be
on the floor).
The compressor operates
continually.
The Temperature regulator may
be set incorrectly.
Set a warmer temperature.
The door is not closed correctly. Refer to "Closing the door".
The door has been opened too
frequently.
Do not keep the door open lon-
ger than necessary.
The product temperature is too
high.
Let the product temperature de-
crease to room temperature be-
fore storage.
The room temperature is too
high.
Decrease the room temperature.
The FROSTMATIC function is
switched on.
Refer to "FROSTMATIC function".
The COOLMATIC function is
switched on.
Refer to "COOLMATIC function".
Water flows on the rear
plate of the refrigerator.
During the automatic defrost-
ing process, frost defrosts on
the rear plate.
This is correct.
Water flows into the re-
frigerator.
The water outlet is clogged. Clean the water outlet.
Products prevent that water
flows into the water collector.
Make sure that products do not
touch the rear plate.
What to do if…
13