Electrolux 335 D Ventilation Hood User Manual


 
47
Technical Details
Model: CHDE 6260 335D
DE 6260
DE 6250
Maximum absorbed power: 330 W 230 W
Fuse rating: T6A 250V T6A 250V
Motor absorption: 2 x 125 W 1 x 150 W
Lighting: 2 x 40 W 2 x 40 W
Duct diameter Ø 120 mm Ø 120 mm
Length of the cable: 150 cm 150 cm
Electrical connection
Safety warnings for the electrician
The electric outlet should be placed on the wall inside the chimney. The
hood has a power cable, 150 cm, with earth connection and the rated
voltage is 220 - 240 V (CHDE 6260/335D) - 230V (DE 6260 - DE 6250).
Connect the hood to the mains supply via a double pole switch
which has 3 mm minimum separation between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow must be connected to
the terminal which is marked with the letter E or by the earth symbol
( ), or coloured green or green and yellow;
- the wire which is coloured blue must be connected to the terminal
which is marked with the letter N or coloured black, -
- the wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.