Electrolux 534077 Dishwasher User Manual


 
Electric Key Information
Water
Warewashing
44 Single Tank Conveyor Dishwasher
without Built In Hot Water Booster WT44
Supply voltage: 534074 (WT44CL208) 208 V/3p/60Hz
534075 (WT44CR208) 208 V/3p/60Hz
534076 (WT44CL240) 240 V/3p/60Hz
534077 (WT44CR240) 240 V/3p/60Hz
Machine requires one electrical connection.
Max. Current absorbed: 208 V/3p/60Hz 61.7A (20.7 kW)
240 V/3p/60Hz 55A (20.7 kW)
Inlet Water supply pressure: 22 – 102 psi (150 – 700 kPa)
Inlet Water supply temperature
Rinse circuit: 194 °F (90 °C)
Wash tank: 80 – 140 °F (27 – 60 °C)
Inlet Water supply hardness: 4 – 8 gpg (7-14 °fH) max
Incoming water line size:
Wash tank: G 3/4
Rinse circuit: G 3/4
Drain line size: 1-1/2
Water consumption: Gallons/hr: 79.25 gal/hr (300 liters)
Water consumption/rack: 0.4 gal/rack (1.5 l/rack)
Wash Temperature: 160 – 172 °F (71-78 °C)
Wash tank size: 26 gal (100 liters)
Wash pump power: 2 hp (1.5 kW)
Rinse Temperature: 180 – 194 °F (82-90 °C)
Rinse pump power: 0.4 hp (0.32 kW)
Rinse pump water flow: 1.32 gal/min (5 l/min)
Initial fill water requirements: 26 gal (100 liters)
Productivity racks per hour 200 racks / 3600 dishes
(max speed): (average 18 dishes per rack)
Productivity racks per hour 130 racks / 2340 dishes
(min speed): (average 18 dishes per rack)
Table to Table connection: 44 (1118 mm)
Number of Tanks: 1
Height with door open: 83-7/16 (2119 mm)
Charging hole size (width): 20-7/8 (530 mm)
Charging hole size (height): 19-3/4 (501 mm)
Net weight: 1012 lb (459 kg)
Shipping weight: 1210 lb (549 kg)
Shipping width: 74-7/16 (1890 mm)
Shipping depth: 40-15/16 (1040 mm)
Shipping height: 81-1/8 (2060 mm)
Shipping volume: 143 cu.ft (4.05 m
3
)
Noise level: <70 dBA
Unit predisposed to accept external detergent dispensers, detergent
probes and rinse aid dispensers.
Exhaust Requirements
Unit supplied as standard with extended vent hoods
(can be removed during installation if not required).
Exhaust extraction not more than 177 CFM (300 m³/h)
Refer to installation diagram for minimum exhaust hood
installation height .