16
It is not necessary to attach the
reinforcement beam to the table
surface, as it is held in place by a
specially designed moulding, which is
incorporated in the hob units flanges.
Installation in work tops with a
base unit underneath
If the hob is to be installed on top of a
base unit, a board must be mounted
underneath the hob (e.g. 16 mm chip
board).
Seal all joints with aluminium tape.
The board can be mounted as shown in
the diagram.
This installation method prevents the
flames from being extinguished if you
close the door of the base unit hard.
If the back panel of the cupboard unit
is of thin 4 mm material, it will need to
be reinforced.
This procedure will prevent the gas
being blown out if the cupboard door
is slammed shut.
Min. 140 mm
Min. 16 mm
Aluminium-tape
Min. 140 mm
Min. 16 mm
Aluminium-tape