Electrolux air-o-chill
Blast Chiller/Freezers 100kg 20GN1/1
Internet: http://www.electrolux.com/foodservice
HDBB0302009-10-06Subject to change without notice
WATER REMOTE UNIT FOR C/FREEZER CW 100KG 880035
TROLLEY TRAY RACK F.16X1/1GN,80MM PITCH 922010
TROLLEY TRAY RACK F. 20X1/1GN,63MM PITCH 922007
RILSAN COATED GRID 881061
PRINTER FOR HACCP BASIC VERSION 881532
PASTRY TROLLEY 16(400X600)80MM-20 1/1 LW 922068
PAIR OF 1/1 GN AISI 304 S/S GRIDS 921101
KIT HACCP EKIS 922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW 880183
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF 880269
BANQ.TROLLEY-54PLATES-74MM PITCH-20GN1/1 922016
AIR/WATER REMOTE UNIT F.BC+BCF LW 100KG 880059
AIR REMOTE UNIT CHILL+C/FREEZER CW 100KG 880031
2 SINGLE SENSOR PROBES CHILLER+C/FREEZER 880096
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER 880089
ACCESSORIES
3-SENSOR PROBE FOR CHILLER+C/FREEZER 1
INCLUDED ACCESSORIES
Net weight - kg. 200
installed-electric 0.88
Power - kW
at evaporation temperature - °C -30
Refrigerant power
Refrigeration power - W 5350
Refrigerant type R404a
N° defrost in 24 hrs. 6
Max load capacity - trays h 65 mm - n° 20
Trays type GN 1/1; 600x400
Door hinges Left
N° and type of door 1
height 1783
depth/with open doors 895, 1422
width 1040
External dimensions - mm
Thermometers Digital
Thermostat Electronic
Control type Electronic
Cooling unit Remote
UK Guide lines - chilling / freezing 100, 85
NF Regulations - chilling / freezing 72, 72
Productivity per cycle - kg.
Type Blast freezer - 100 kg
TECHNICAL DATA
AOFP201CRR
727152
CONSTRUCTION
• Automatic heated door frame.
• Internal and external finishing in 304
AISI stainless steel and back panel in
stainless steel.
• High density polyurethane
insulation, 60 mm tickness, HCFC
free.
• Environmentally friendly: R404a as
refrigerant fluid.
• Developed and produced in ISO
9001 and ISO 14001 certified factory.
• Inner cell with fully rounded corners.
• Door equipped with removable
magnetic gasket with hygienic design.
• All motors and fan waterproof
protected IP20.
• Evaporator with anti rust protection.
• Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
• Hot gas defrosting system.
• Solenoid valves.
• 1 thermostatic expansion valve.
• Feet 200 mm high.
• Stand alone printer as optional, built
in on request.
• PC connection on request, gate RS
485.
INSTALLATION
• No water connections required.
• Waste can be plumbed into drain,
but can also be collected in optional
waste container.
Installation diagram:
C - Water drain
I - Electrical connection
Y - Connection for appliance lifting
L - Remote electrical connection
N - Cooling water inlet
O - Cooling water outlet