Supply voltage:
267554 (AOS201GAP1) 120 V/1p/60Hz - 7.3A
Circuit breaker required:
Electric
The company reserves the right to make modifications to the products
without prior notice. All information correct at time of printing.
8-11-09
Front View
Top View
Side View
air-o-steam
®
Gas Combi Oven 201
Gas (Natural or LPG)
ISO 7/1 Gas connection diameter: 1 MNPT
Gas regulator recommended. Supplied by others.
Max rated thermal load:
Natural Gas
Pressure: 7 w.c. (17.4 mbar)
Steam generator: BTU 116,000 (34 kW)
Heating elements: BTU 170,600 (50 kW)
Total: BTU 286,600 (84 kW)
LPG
Pressure: 11 w.c. (27.4 mbar)
Steam generator: BTU 102,400 (30 kW)
Heating elements: BTU 153,600 (45 kW)
Total: BTU 256,000 (75 kW)
Gas (Natural or LPG)
Net weight: 551 lbs. (250 kg)
Shipping weight: 640 lbs. (290 kg)
Shipping width: 41-3/4 (1060 mm)
Shipping height: 81-1/8 (2060 mm)
Shipping depth: 39 (990 mm)
Shipping Volume: 76.5 cu. ft. (2.16 m³)
Key Information
Water Consumption (gal./hr.): Min: 4.49 Max: 20.08
Water inlet “CW” – ¾
connection:
Unfiltered drinking water
Water inlet “FCW” - ¾
connection:
Total hardness: 5-50 ppm
Pressure: 22-36 psi (150-250 kPa)
Drain “D”: 1-1/4 connection
Electrolux recommends the use of treated water, based on
testing of specific water conditions.
Please refer to user manual for detailed water quality information.
Water
Clearance: 2 (5 cm) rear and right hand sides.
Suggested clearance
for service access: 20 (50 cm) left hand side.
Installation
Steam pans: 20 – 12 x 20
Half size sheet pans: 20 – 13 x 18
GN: 20 – 1/1 containers
Max load capacity: 220 lbs. (100 kg)
Capacity