12.7 Gas regulations
If the cooking appliance is set up for a
different
type of gas than that available, its injectors must
be replaced, the minimum flow regulated. In order to replace the injectors in the cooking hob, it is
necessary to carry out the following operations:
remove the pan supports;
remove the burners and burner caps (
Fig. A
);
take out the injector (
Fig. B
) and replace it with one
suitable for the new type of gas (see "
G
ENERAL
INJECTORS TABLE
");
replace the gas label (on the rear of the appliance) with
the new one provided with the injectors kit;
refit all parts by following the disassembly instructions in
reverse order and taking care to position the burner cap
correctly on the burner.
12.7.1 Minimum flow of valved cooking hob taps
Switch on the burner and turn the control knob
towards the minimum flow position
;
remove the knob;
using a screwdriver, adjust the internal screw
Z
until the correct low flame is obtained;
refit the knob.
12.7.2 Minimum flow of non-valved cooking hob taps
Switch on the burner and turn the control knob
towards the minimum flow position
;
remove the knob;
insert a small screwdriver into the rod of the tap
and adjust the internal screw
Z
until the correct
low flame is obtained;
refit the knob.
Unscrew the adjustment screw Z to increase the flow, or tighten it to reduce the flow.
The adjustment is correct when the low flame measures approximately 3 or 4 mm.
When changing quickly from maximum to minimum flow and vice versa make sure that the
flame does not go out.
GENERAL INJECTORS TABLE
POWER Watt CONSUMPTION
TYPE OF GAS mBar NOZZLE NO.
BURNERS
POSITION TYPE
MAX. MIN. MAX.
115 RAPID 3000 750 286 l/h
97 SEMI RAPID 1750 480 167 l/h
72 AUXILIARY 1000 330 95 l/h
128 TRIPLE-RING 3300 1300 314 l/h
NATURAL GAS 20
94 FISH KETTLE 1900 750 181 l/h
85 RAPID 3000 750 219 g/h
65 SEMI RAPID 1750 480 128 g/h
50 AUXILIARY 1000 330 73 g/h
93 TRIPLE-RING 3300 1300 241 g/h
LPG
BUTANE
PROPANE
30
28
37
68 FISH KETTLE 1900 750 138 g/h
12.8 Connecting to LPG
Use a pressure regulator and connect to the cylinder in compliance with the guidelines set out in
standards regulations in force.
Note: L.P.G.
cookers
MUST NOT
be installed below ground level i.e. in a basement or aboard any
boat, yacht or other vessel.