6
INSTALLATION
This cooker must be installed in
accordance with the IEE Wiring Regulations
(Current Edition). Detailed recommendations
are contained in the following British
Standards Codes Of Practice:
B.S. 6172/ B.S. 5440, Par.2 and B.S. 6891
Current Editions.
The appliance must be installed in accordance
with " X " specification (EN60.335-2.6). The
cooker must not be installed higher than the
worktop.
Please ensure that when the appliance is
installed it is easily accessible for the
engineer in the event of a breakdown.
Before your appliance is connected to the mains
electricity supply, check to ensure that the
voltage and the frequency shown on the rating
plate corresponds with your supply voltage.
This appliance must be earthed.
The manufacturer declines any
responsibility for possible damages resulting
from an installation which doesn't comply
with current legislation.
- Installation of flues and ventilation for gas
appliances of rated input not exceeding
60 kW (1
st
, 2
n
d
and 3
r
d
family gases) – Part
2 Specification for installation of
ventilation for gas appliances – BS 5440;
- Gas burning appliances – Part 3 Domestic
cooking appliances burning gas – BS
5386;
- Specification for installation of low
pressure gas pipe work of up to 20mm
(R1) in domestic premises (2
n
d
family gas)
– BS 6891;
- Pipe threads for tubes and fittings where
pressure-tight joints are made on the
threads (metric dimensions) – BS 21:
1985;
- Flexible hoses, end fittings and sockets
for gas burning appliances – BS 669;
Installation of domestic gas cooking appliances
(1
st
, 2
nd
and 3
rd
family gases) – BS 6172: 1990;
LOCATION
Remove all the packaging and install the cooker
in a dry, ventilated room not near curtains, paper,
alcohol, petrol etc (See figure).
The appliance must be set on a heatproof
floor. The adjustable feet must not be
removed.
L.P.G. cookers or ovens MUST NOT be
installed below ground level, i.e. in a
basement, or aboard any boat, yacht or other
vessel.
This appliance is approved to class “1” regarding
overheating of surrounding surfaces.
It is mandatory to keep 20mm distance to the
adjacent furniture.
The cooking appliance must be fitted
with a stability chain firmly secured to the
wall (see fig).
Ventilation
The room containing the cooker should have an
air supply in accordance with B.S. 5440: Part 2:
Current Editions.
The following requirements for ventilation must
be met.
20mm
20mm
62 cm
69cm
20mm
20mm
69cm
15 cm
or
Electrolux Pr emier
Electrolux Premier
Firmly fix
chain to rear
of cooker
Stability hook
Stability chain
Chain to be as short
as possible.