Electrolux E30MH65GPS Microwave Oven User Manual


 
Over-the-Range Microwave
E30MH65GPS professional series
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E30MH65GPS 03/08 © 2008 Electrolux Home Products, Inc. Printed in the U.S.A.
30" Over-the-Range Microwave Specifications
Product Weight – 75 Lbs.
Voltage Rating –120V/60Hz/20 Amp
Connected Load (kW Rating) @120 Volts = 1.6kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
Amps @ 120 Volts =14.5 Amps
Always consult local and/or national electric codes.
Grounded outlet should be located in cabinet above, with hole in base
to route power cord. Carefully follow top template instructions for power
cord clearance when installing beneath smooth, flat cabinets.
Microwave’s ventilation system is convertible, designed for two
types of exhaust – outside, using either vertical or horizontal ducting;
or recirculating, requiring no ducting.
For safe and proper installation, microwave MUST be mounted to
BOTH a top cabinet AND a wall, and connected to at least one wall stud.
Can NOT be installed in island or peninsula cabinet arrangements.
Cabinet bottom MUST be level to insure proper installation.
Cabinet MUST be capable of supporting a total load of 110 lbs.
Filler blocks recommended for installation when cabinet front hangs
below recessed bottom shelf.
Minimum distance of 33" required from cooking surface to bottom
edge of top cabinet.
Minimum distance of 69" required from floor to top of microwave.
Opening between cabinets MUST be 30" wide and free of obstructions.
Can only be installed over ranges or cooktops with 33" maximum width.
Allow 25-1/2" minimum clearance for 90° door swing.
Ducted Option Specifications
For outside ventilation only.
Exhaust duct adapter supplied assembled for outside ventilation,
designed to mate with standard 3-1/4" x 10" rectangular duct. If round
duct required, rectangular-to-round transition adapter will be needed
with no less than 6" diameter.
For most efficient airflow exhaust, use a straight run or as few elbows
as possible with maximum duct length of 3-1/4" x 10" rectangular
or 6" diameter round duct, not to exceed 140 equivalent feet.
For horizontal installation, be sure to allow enough space between wall
studs to accommodate exhaust.
Refer to web for detailed duct preparation instructions.
Ductless (Recirculated) Option Specifications
If ducting to outside is not an option, ventilation system can be converted
to ductless to recirculate air inside.
Refer to web for detailed convertible ventilation installation instructions.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
5"min.
Backsplash
Rear Wall
16
1
/2"
min.
30"min.
69"min.
from floor
to top of
microwave
Bottom edge of
cabinet MUST be
33"min. from
cooking surface
Cabinet MUST
be capable of
supporting a total
load of 110 lbs.
12"
min.
33"
min.
Microwave MUST
be mounted to
BOTH a top cabinet
AND a wall*
Locate 120V/60Hz grounded outlet inside upper cabinet
*Can NOT be installed
in island or peninsula
cabinet arrangements
30"min.
33"max.
16
3
/8"
29
7
/8"
14
3
/8"
Blower plate allows for vertical
or horizontal ducting
Power cord location
(right top rear)
16
7
/8"
1
/2" lower
extrusion
Allow at least 25
1
/2" clearance
for door depth when open
16
1
/8"