Electrolux E36GC76GPS Cooktop User Manual


 
Gas Slide-In Cooktop
E36GC76GPS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E36GC76GPS 05/08 © 2008 Electrolux Home Products, Inc. Printed in the U.S.A.
36" Gas Slide-In Cooktop Specifications
Product Weight – 115 Lbs.
Voltage Rating –120V/ 60Hz/15 Amp
Connected Load (kW Rating) @120 Volts = 0.001kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @120 Volts = 0.008 Amps
Always consult local and/or national electric and gas codes.
Cooktop ships with 3/4" factory regulator.
Lp conversion kit supplied.
Plan installation to have electrical connection, gas shutoff valve, and
pressure regulator accessible from front of cabinet. Locate 120V
grounded outlet in a 4"W x 5"H area on rear wall, 16" above floor,
aligned center with cooktop.
Cabinet and/or countertop must completely enclose recessed portion
of cooktop. Respect cutout dimensions and clearances and ensure
that all contact surfaces are solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No.28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
Allow 1" minimum clearance between rear edge of cooktop and nearest
combustible surface above countertop. If required clearance can not be
maintained, then optional stainless steel backsplash or noncombustible
backsplash material must be used – otherwise installation will require
custom cabinet and countertop dimensions.
Allow 7" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
It is recommended that drawers not be used beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 7" beyond bottom
of cabinets.
Gas Slide-In Cooktop model E36GC76GPS is NOT approved to be used
over any Electrolux ICON
Single Wall Oven.
Gas Slide-In Cooktop model E36GC76GPS (without optional backsplash)
is approved to be used in combination with an Electrolux ICON
Downdraft Vent. (Refer to Slide-In Cooktop/Downdraft Vent Countertop
Preparation Specifications page and on web.) Proper combination
installation will require cooktop power cord to be relocated to underside
of unit. (For details, refer to 30" & 36" Gas Slide-In Cooktop Power Cord
Relocation Instructions on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
When replacing an existing cooktop with countertop cutout deeper
than 7-1/4" and less than 8-1/2", order free Depth Adjustment Filler Kit –
(903051-9010).
9" Stainless Steel Backsplash – (903048-9010).
Black Knobs Kit – (903049-9120).
25"
35
7
/8"
2"
36" min.
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. with
protected bottom
surface
**Applies only in case
of countertop backwall
7
3
/4"
Side inset
5
/8"
Optional 9" stainless
steel backsplash
(attaches to wall)
35
15
/16"**
1
1
/8"
max.
Support
platform
7
1
/2"
35
3
/16"*
35
15
/16"*
1" countertop
overhang
*Both cutout dimensions are
critical to proper cooktop installation.
Due to variations in countertop materials it
is recommended to undercut finished dimension
35
15
/16" and adjust upon installation of cooktop.
7
1
/4"
3
/8"
24"
1" min. recommended distance between
rear edge of cutout and nearest combustible
surface above countertop
2"
3"
2" dia.
opening to route
power cable
2
1
/2"
7" min. to nearest
combustible wall
(either side of unit)
4" x 4" opening to
route gas supply
22
1
/8"
35
1
/8"