Electrolux E36GF76JPS Double Oven User Manual


 
Full-Gas Freestanding Range
E36GF76JPS professional series
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E36GF76JPS 05/11 © 2011 Electrolux Home Products, Inc. Printed in the U.S.A.
36" Full-Gas Freestanding Range Specifications
Product Weight – 352 Lbs.
Voltage Rating –120V/ 60Hz/15 or 20 Amp
Connected Load (kW Rating) @120 Volts = 0.6kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Amps @120 Volts = 7 Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90°F above room
temperature without shrinking, warping or discoloring. Insulating pad or
1/4"-thick plywood required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base or
beneath lower front panel of range. Range requires fresh air for proper
burner combustion.
Range ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Gas supply piping can be routed through side wall of right cabinet. Right
side cabinet is ideal location for main shutoff valve.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Allow 34" minimum clearance between top of rangetop and bottom
of unprotected wood or metal overhead cabinetry; 28" minimum
clearance when bottom of wood or metal overhead cabinet is protected
by not less than 1/4" flame-retardant millboard covered with not less
than No.28 MSG sheet metal, 0.015" stainless steel, 0.024" aluminum
or 0.020" copper.
Allow 7" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond
bottom of cabinets.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
9" Stainless Steel Backsplash – (PN# 903134-9100).
4" Stainless Steel Kick Plate – (PN# 318352652).
Black Knobs Kit – (PN# 903108-9020).
E36GF76JPS