42" Built-In Refrigerator Specifications
Product Weight – 610 Lbs.
Voltage Rating –120V/ 60Hz/15 or 20 Amps
Connected Load (kW Rating) @120 Volts = 0.65kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
Amps @120 Volts = 5.4 Amps
Always consult local and/or national electric & plumbing codes.
Cutout must be prepared with electrical and water supply located as
shown. When possible, recess copper water line and electrical outlet.
Water line can enter opening through floor or rear wall. Copper tubing
recommended between cold water line and water connection location.
Water line tubing recommended is 48" minimum length by 1/4" diameter.
Installation of easily accessible shutoff valve in water line required.
Optimum door swing factory set for 130°. When installing next to wall
where handle may make contact, allow 4" minimum clearance for 90°
door swing. At 90° door stop position, drawer access will be maintained
but removal will be restricted.
Refrigerator must be placed on level surface of hard material, same
height as flooring. Surface must support approximately 1500 Lbs. when
fully loaded. Unit equipped with 4-point leveling.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Door-Swing Clearances
Refrigerator equipped with 2-position door
stop. Factory set to 130°, adjustable to
90° if clearance to adjacent cabinets or
wall is restricted.
130
°
Door Swing
12
3
/16"
41"
16"
24"
23
7
/8"
behind
frame
41"
90°
Door Swing
4"min. to wall
B
7"x 7"
electrical
area
74"from
floor to
bottom of
electrical
area
Water
supply
A
5"
C
3"
3
1
/2"
3
1
/2"
Cutout
Dimensions
(A) Finished
opening:
83
1
/2"min.
84
1
/2"max.
(B) 41
1
/2"
(C) 24"
Notes:
A 4" min. door clearance is required when
using 90° door stop position. Drawer access
is maintained, but removal is restricted.
To determine door swing interaction with
adjacent cabinets and countertops refer to
Product Installation Guide on web at
electroluxicon.com
.
Power cord location
(right top rear)
Water line inlet location
(left bottom front)
*Shipping height. (Front height may be adjusted from 83-1/2"
to 84-1/2" by adjusting leveling legs a max. of 1".)
41"case width
84"
from
floor
to
top
frame
25
3
/8"
*83
3
/4"
at rear
42"
frame to frame
26
7
/8"
including
handle