Electrolux E46DD75ESS Ventilation Hood User Manual


 
13
Installing the Blower
BLOWER INSTALLATION
Mount the blower to the wall or roof using screws,
through mounting trim flange.
Verifying Proper Operation
1 Temporarily re-install the remote blower
cover, using 2 screws per side).
2 Turn on the power supply at the circuit
breaker.
3 Refer to the Retractable Vent Installation
Instructions for further instructions on
verifying the proper operation.
IMPORIMPOR
IMPORIMPOR
IMPOR
TT
TT
T
ANTANT
ANTANT
ANT
If the remote blower does not operate properly, follow these troubleshooting steps:
1. Verify that power is being supplied to the Retractable Vent and the remote
blower.
2. Check the electrical connections to ensure that the installation has been
completed correctly.
3. Repeat the above test.
4. If the appliance still does not work, contact Electrolux at 1-877-4Electrolux. Do
not attempt to repair the appliance yourself. Electrolux is not responsible for
service required to correct a faulty installation.
N1
L1
N2
L2
N2
Gnd
BLK
WHT
120VAC, 60Hz, 15A
Supply power from
dedicated circuit breaker
GRN
WHT
L2
BLK
BLK
WHT
Gnd
GRN
Gnd
GRN
GRN
WHT
BLK
Blower
5304444802
Vent
Wiring of Retractable Ventilation System
(E30DD75ESS, E36DD75ESS, E46DD75ESS
and E48DD75ESS)
Figure 7