9
IInnssttaallllaattiioonn
Positioning
Place the freezer horizontally on a firm surface,
resting on all four feet/wheels. Use a wooden block
or similar object to compensate for any
bumps/holes in the surface.
The room should be dry and adequately ventilated.
If the room temperature exceeds 32°C, or falls
below freezing point, the freezer will not function as
it should.
Do not place the freezer close to sources of heat,
radiators, chimneys, etc., and do not place the
freezer in direct sunlight.
If the freezer has been handled standing on end it
should be allowed to stand in normal position for
about 12 hours before switching it on.
Please ensure that when the appliance is installed
it is easily accessible for the engineer in the event
of a breakdown.
Model ECN 1040
Volume (gross) litres 105
Volume (net) litres 102
Height without/with roller cm 85,5/86,1
Width cm 55
Depth cm 55
Weight kg 33
Energy consumpt./24h kWh 0,68
Freezing capacity kg/24h 13
Hold-over time hours 18
Rated power W 60
Technical Specifications