Electrolux EFC950 Ventilation Hood User Manual


 
38
Installation
Unpacking
Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transport
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.
Placement
The hood is to be mounted on the wall.
When installed, the hood must be not less than 60
cm. above electric burners or 75 cm. above gas or
mixed-fuel burners (fig. 7).
Electrical connection (not for
UK)
Safety warnings for the electrician
Before connecting the appliance to the power
supply, check that the voltage indicated on the
rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be
connected to any standard power socket within
easy access.
Should it be necessary to provide a fixed
connection, the hood must only be installed by an
electrician authorised by the local electricity board.
When installing, an omnipolar disconnector with a
distance of at least 3 mm between contacts must
be provided.
Fixed connection of the appliance must only be
carried out by an authorised electrician.
Electrical connection for UK
only
Safety warnings for the electrician
Connect the hood to the mains supply via a double
pole switch which has 3 mm minimum separation
between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N or coloured black, -
- the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L or coloured red.
Min
75 cm
Min
60 cm
Fig. 7