Electrolux EFG 520 Ventilation Hood User Manual


 
12
A: Built-in Electric Hob: 650mm minimum clearance
B: Built-in Gas hob: 700mm minimum clearance
C: Slot-in Electric Cooker: 685mm minimum clearance
D: Slot-in Gas Cooker: 787mm minimum clearance
Hob
Clearance Height
A minimum clearance height of 650mm
(25 1/2 ”) is required when installed above a
built-in electric hob, or 700mm (27 1/2 ”) when
installed above a built-in gas hob.
A minimum clearance height of 685mm (27”)
is required when installed above a slot-in
electric cooker, or 787mm (30 1/2 ”) when
installed above a slot-in gas cooker.
When installed between adjoining wall
cabinets, the wall cabinets must not overhang
the hob and the distance between the
underside of the cabinet and the worktop must
be 450mm. If the height of the wall cabinet is
less than 450mm, a gap of 50mm must be
maintained either side of the hob.
This cooker hood must not be installed above
a cooking appliance with a high level grill.
Unpacking
The fittings supplied to install this cooker
hood can be found with the instruction book
inside the packaging:
10 x 13mm fixing screws
120 - 125 mm ducting collar
Fitting the Cooker Hood into the
Housing/Canopy
The hood is fixed to the housing using the
screw holes located around the base of the
casing. Access to the screw holes will
require the removal of the metal grille panel.
Positioning the Cooker Hood
Measure the underside of the canopy or
kitchen cabinet to mark the position for the
cut-out. The cut-out measurement should be:
- 497mm (19 5/8”) wide
- 259mm (10 1/4”) deep
Check the position of the hole is correct
with the measurements above before
making the cut-out.
The hood is fixed using the holes located in