Electrolux EFT60002 Ventilation Hood User Manual


 
Installation electrolux 7
EN
INSTALLATION
2 - INSTALLATION INSTRUCTIONS
Some installation systems require the
opening and removal of the metal grille
panel.
2.1 - Instructions for opening and
removing the metal grille panel
To open the grille panel, press inwardly
on the two slider catches at each side
of the grille panel and the grille will pivot
down.
To remove the metal grille, pull forward
on the right hand side so that the hin-
ge pin on the back of the grille will be
released from the slot in the side of the
casing.
2.2 - Wall cabinet xing
a-Predrilled wall cabinet: x the hood
onto the wall cabinet base panel using
the four screws 4.2 x 45 mm (supplied
with the xing kit).
It is not necessary to open the metal
grille.
b-No predrilled wall cabinet:
b.1-If the hood is provided with a pa-
per xing template, follow the instruc-
tions.
b.2-If the hood is not provided with
a paper xing template, position the
hood on the wall cabinet base panel
and pilot drill the 3.5 x 16 mm screws
(not supplied with the xing kit) from
the inside onto the wood.
2.3 - Wall mounting
a-Drill two Ø 8 mm holes on the wall us-
ing the paper template, insert two rawl
plugs and two 4.2 x 44,4mm screws
leaving 5 mm untightened. Open the
metal grille panel, hook the hood on
and fully tighten the screws.
b-If the hood is not provided with a pa-
per xing template, drill two Ø 8mm
holes (see draw.), insert the plugs and
screws, proceeding as directed under
paragraph a.
c-For wall mounting using wallbrackets
(optional), follow the instructions of
the xing template.
d-Pay attention to the safety regulation
of point 1.6.
2.4 - Choice of operating mode
a - Evacuation mode
To check that the hood is set up for
evacuation, open the grille panel and
make sure that the conversion lever or
the change-over knob on the centrifugal
unit is in the DUCTING position. The
charcoal lter is not required.
For ducting to the outside, the hood is
supplied with a rear and top outlet. A
ange spigot of 100 mm diameter (120
mm in certain models) is usually tted
on the top outlet and a blanking plug on
the rear outlet. If you choose to duct the
hood from the rear of the casing, you
should invert the position of the ange
and of the blanking plug. Pay attention
to the safety regulation 1.1.
b - Internal recirculation mode
To check that the hood is set up for
recycling, open the grille panel and
make sure that the conversion lever or
the change-over knob on the centrifugal
unit is in the RECYCLING position. The
charcoal lter is to be tted. To t the
charcoal lter, support the lter with one
hand and turn the thumb screw through
the centre of the charcoal lter. If the
lter is of the interlocking type, turn the
lter clockwise. The hood can remain
connected to the outside.
2.5 - Electrical connection and
working test
1-The safety measures 1.2, 1.3, 1.4 and
1.5 of paragraph 1 are to be strictly
observed.
2-Once the electrical connection has
been completed, check that the
worktop illumination, motor and
speeds work properly.