Installation
Fig. 9 - Wall mounting
Mounting accessories included
4 screws 5 x 45 mm
4 wall plugs (brick fixing) Ø 8 mm
4 screws 4,2 x 35 mm
1 flange Ø 125 mm
1 allen spanner (for TORX screws)
1 screw 2.9 x 13
Wall unit mounting
Make the holes on the bottom of the cupboard
(2), using the drilling template (1).
Make a hole for the exhaust pipe (4) if the hood
is to be used in the extraction version (3).
From inside the cupboard, insert the 4 supplied
screws (5) and tighten them in the appropriate
holes on the appliance.
Wall mounting
Mark a centre line on the wall (1).
Fit the template onto the wall (2).
Fix the drilling template to the wall.
Make 3 Ø 8mm holes in the wall (3), 2 at upper
points, 1 as desired at lower points.
Insert the three Ø 8mm expansion plugs into the
wall (4) (brick fixing only)..
Insert 2 5x45 screws (5) but do not tighten them
completely, hang the hood (6).
Adjust the unit so that it is positioned at a right
angle to the wall by turning the two screws on
lower side (7).
Tighten the 2 upper screws (8).
From inside the hood, insert the third 5x45
screw into the lower hole (9) and tighten (10).
Fig. 8 - Wall unit mounting