Electrolux EFT 625 Ventilation Hood User Manual


 
4
D
E
G
H
D
E
F
0 I
0 I 2 3
EFT 625 - 925
1. Light switch
2. Motor speed switch
3. Work light
4. Suction grid with grease filter
Standard accessories included:
l Template for mounting on wall and under
cupboard
l Screws:
l Duct with no return valve
l Plug for unused outlet hole
Function
The hood may be used as follows:
- For air exhausting
- For air recycling
Attention! The Cooker hood is ready to be used for
air recycling (carbon filter already mounted in
place).
Exhausting
The appliance has two exhaust outlets; D and E
(Fig. 2).
Important! To use the back hole E, remove air
switch F from the top hole.
Connect the hood to the smoke exhaust hose by
using the connecting ring G with no return valve
(bayonet coupling).
Insert plug H in the unused exhaust hole (bayonet
coupling).
Plug H is for closing the unused hole.
Attention! In the horizontal runs the duct must be
slightly slanted (about 10°) and directed upwards
to vent the air easily from the room to the outside.
The hood cannot be connected to flues
of other appliances that run on
energy sources other than electricity.
Recycling
The air is filtered through a carbon filter and
recirculated into the room through the front grid
(fig. 3).
This version is used when there is no exhaust duct
for venting outdoors or when it is impossible to
install one.
Description of the appliance
Fig. 2
Fig. 3
Fig. 1
3
4
1
2