Electrolux EHG60412 Cooktop User Manual


 
Important! The replacement of electric
cable must be carried out exclusively by the
service force centre or by personnel with
similar competencies, in accordance with
the current regulations.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.
Building In
min. 600 mm
min. 55 mm
min. 650 mm
550 mm
470 mm
min. 100 mm
30 mm
A
B
A - supplied seal
B - supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
b
a
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the
indication and the kitchen unit must be
equipped with vents to let a continuous
supply of air. The electrical connection of
the hob and the oven must be installed
separately for safety reasons and to let easy
remove oven from the unit.
50 cm
2
360 cm
2
180 cm
2
120 cm
2
MANUFACTURER:
ELECTROLUX ITALIA S.p.A.
C.so Lino Zanussi, 30
33080 PORCIA (PN) - ITALIA
electrolux 7