7
Overall dimensions
Width: 580 mm.
Depth: 500 mm.
Cut out dimensions
Width: 550 mm.
Depth: 470 mm.
Ignition HT Spark
Spark Generator Ispra Control's BF 50066 -
220-240V 0.6 VA T 120
Spark Gap Fixed
Rear Left Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input 3.0 kW (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
Rear Right Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input 1.0 kW (3413 BTU/HR)
Supply connections
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
Instructions for the Installer
Engineers technical data
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL 3.0 0.65 2.0 0.45 1.0 0.33
POWER (kW)
NOMINAL FLOW 0.286 0.062 0.190 0.043 0.095 0.031
RATE (m
3
/h)
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
(1/100 mm)
NOMINAL THERMAL 2.8 0.65 2.0 0.45 1.0 0.33
POWER (kW)
NOMINAL FLOW 202 47 144 32 72 24
RATE (g/h)
NOZZLE REFERENCE 86 40 71 32 50 28
(1/100 mm)
NATURAL
GAS
20 mbar
TYPE OF
GAS
Characteristics
LPG GAS
28-30/37
mbar
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 40
Aeration adjustment none
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II2H3+