Electrolux EKG5047 Range User Manual


 
27
TECHNICAL DETAILS
DIMENSIONS
Height: 900 mm (nominal)
Width: 500 mm (nominal)
Depth: 600 mm (to front of door panel)
Weight: 54 .4 Kg Net
Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level. See important note 'Location of Appliance'.
Minimum space above hotplate 750mm (If cooker hood is fitted refer to the cooker hood installation instructions.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel)
CONNECTIONS
Gas connection: - Rear left hand side of appliance at hotplate level
Rc ½ (½” B.S.P. female)
Electrical connection: - None
IGNITION Battery 1.5 Volt AA size
HOTPLATE
Natural Gas
Heat Input R.H.F R.H.F L.H.R L.H.F
1.0kW 1.9kW 1.9kW 2.9kW
(3412 Btu/h) (6483 Btu/h) (6483 Btu/h) (9895 Btu/h)
Injector Marking 070 096 096 119
L.P.Gas
Heat Input 1.0kW 1.9kW 1.9kW 2.8kW
(71.8g/h) (136.5g/h) (136.5g/h) (194.0g/h)
Injector Marking 050 071 071 086
GRILL Natural Gas L.P.Gas
Heat Input 2.7kW (9215 Btu/h) 2.7kW (176g/h)
Injector Marking 121 78
SECOND OVEN
Heat Input 2.4kW (8189 Btu/h) 2.4kW (172.4g/h)
Injector Marking 108 078
Dual Control By-Pass Fixed Internal Fixed Internal
MAIN OVEN
Heat Input 2.4kW (8189Btu/h) 2.4kW ( 172.4g/h)
Injector Marking 108 78
Thermostat By-Pass Marking 69 48
GENERAL
Ignition (H.T. Spark)
Spark Gap 3-4mm
GAS CATEGORY COUNTRIES OF DESTINATION
CAT. I
2H GB
CAT. I
3+ GB
This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC ,Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68/EEC.