CONNECTING TO GAS SUPPLY
This appliance is designed to be installed with an
appliance flexible connection only. Supply piping
should not be less than R
3/8. Connection is made to
the Rc ½ (½” B.S.P.) female threaded entry pipe
located just below the hotplate level on the rear left
hand side of the appliance. NOTE: ONLY LIQUID
SEALANTS TO BE USED WHEN INLET GAS PIPE
IS FITTED I.E.: DO NOT USE P.T.F.E. SEALANT
TAPE. Carry out a gas tightness test after
connecting to the gas supply. The gas bayonet
connector must be fitted in the shaded area
indicated in Fig.3. Take into account that it must be
possible to pull the appliance forward sufficiently.
Ensure the hose does not become trapped when
pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING USED MUST
COMPLY WITH BS.669 CURRENT EDITION.
LPG Flexible connections must be a type suitable for
L.P.G and capable of operation up to 50 mbar and
carry a red stripe, band or label.
FITTING THE STABILITY CHAIN
It is recommended that if the appliance is to be
installed with a flexible supply pipe, a stability chain
be fitted and is available from your supplier (see
Important Safety Requirements). These instructions
should be read in conjunction with any leaflet packed
with the stability chain.
1. Place the appliance in its intended position and
level appliance.
2. Mark a position 100mm from the top of the rear
right hand corner.
3. Measure down 150mm from this point. This
gives the position of the wall anchor point for the
stability chain.
4. The stability chain anchor point on the appliance
is shown in the diagram Fig. 4.
PRESSURE TESTING
1. The Rapid injector is used as a pressure test
point.
2. Connect the pressure gauge to the Rapid
injector.
3. Check the supply pressure by turning the Rapid
burner on and one other hotplate burner full on
and light the appropriate burner. The pressure
should be either:-
(i) For Natural Gas 20mbar
(ii) For LP. Gas. The pressure must be set
to 29 mbar for use on butane or 37 mbar
for use on propane.
4. Turn off the taps, disconnect the pressure
gauge.
5. Check operation of each hotplate burner.
Fig.3.