Electrolux ER 7626 B Refrigerator User Manual


 
5
OPERATION
Before using
Remove all securing tapes. Wash inside the
appliance with lukewarm water and bicarbonate of
soda (5 ml to 0.5 litre of water).
Do not use soap or detergent as the smell may
linger. Dry thoroughly.
Setting the temperature
The temperature inside the appliance is regulated by
a thermostat with 6 temperature positions and an
“OFF” (O) position.
Position 1 = minimum coldness
Position 6 = maximum coldness
Turn the thermostat dial to the required position.
The intermediate position is usually the most
suitable (3-4).
The thermostat control regulates the temperature
both within the fridge and the freezer compartment.
The thermostat setting can vary as the temperature
inside the appliance depends on the following
factors:
– room temperature
how often the door is opened
how much food is stored
position of the appliance
Fresh food refrigeration
To obtain the best performance, do not store warm
food or evaporating liquids in the refrigerator; cover
or wrap the food, particularly if it has a strong flavour.
Do not cover the shelves with any protective
material, such as paper, cardboard or plastic, which
may obstruct the air circulation.
To help you use your refrigerator correctly, here are
some more useful hints:
Raw meat (beef, pork, lamb & chicken or poultry):
wrap in polythene bags and place on the glass shelf
above the salad drawers.
Meat can only be stored safely in this way for
one or two days at the most.
Fruit & vegetables: these should be thoroughly
cleaned and placed in the salad drawers.
Butter & cheese: these should be placed in special
airtight containers or wrapped in aluminium foil or
polythene bags to exclude as much air as possible.
Milk bottles: these should have a cap and should be
stored in the bottle rack on the door.
To Start the Appliance
Allow the appliance to stand for 2 hours after
installation.
Plug in the appliance and switch on at the mains
supply. Open the fridge door. Turn the thermostat
control to a midway setting (3-4) and adjust the slider
control, situated on the back wall of the fridge
section, to a midway position between “MIN” and
“MAX”. Leave the appliance for approximately 4
hours for the correct temperature to be reached
before placing food inside.
To switch off the appliance turn the thermostat
control to position “O”
Use of an air circulation slider
control - COOL FLOW CONTROL
Your appliance has an air circulation slider control
situated at the rear of the fridge compartment, which
controls the amount of cold air circulated through the
fridge compartment.
When the ambient temperature is between 10°C and
16°C, the slider control should be in the “MIN”
position.
When the ambient temperature is above 16°C the
slider control should be midway between “MIN” and
“MAX”.
When the ambient temperature is very high (i.e. hot
summer days) position the slider control to “MAX”.
D757/1
MIN
MAX
COOL FLOW CONTROL
MIN MAX
COOL FLOW CONTROL
16
Electrical connections
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability should
this safety measure not be observed.
If the plug that is fitted to your appliance is not
suitable for your socket outlet, it must be cut off and
the appropriate plug fitted.
Remove the fuse from the cut off plug.
The cut off plug should then be disposed of to
prevent the hazard of shocks in case it should be
plugged into a 13amp socket in another part of your
home.
Important
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
If you fit your own plug, the colours of the wires in
the mains lead of your appliance may not
correspond with the markings identifying the
terminals in your plug, proceed as follows:
Connect the Green and Yellow (earth) wire to the
terminal in the plug which is marked with the letter
«E» or the earth symbol or coloured green and
yellow.
Connect the blue (neutral) wire to the terminal in the
plug which is marked with the letter «N» or coloured
black.
Connect the brown (live) wire to the terminal in the
plug which is marked with the letter «L» or coloured
red.
The plug moulded onto the lead incorporates a fuse.
D207
GREEN & YELLOW
13 AMP. FUSE
BROWN
CORD CLAMP
BLUE
13 AMP
For replacement, use a 13amp BSI362 fuse. Only
ASTA or BSI approved fuses should be used.
The plug must not be used if the fuse cover/carrier is
lost. The cover/carrier is indicated by the coloured
insert at the base of the plug.
A replacement cover/carrier must be obtained from
your local Service Force Centre.
This appliance complies with the E.E.C. Directive
No. 87/308 of 2.6.87 relative to radio interference
suppression.
This appliance complies with the following
E.E.C. Directives:
- 73/23 EEC of 19.2.73 (Low Voltage Directive)
and subsequent modifications;
- 89/336 EEC of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent
modifications.
Please ensure that when the appliance is
installed it is easily accessible for the engineer in
the event of a breakdown.