Electrolux ERES35800 Refrigerator User Manual


 
18
O
nly gas comes out when
opening
Incoming water pressure too high. Install a
pressure-limiting device.
Capacity temporarily exceeded. Wait for ten
minutes.
The water dispenser lamp and
the yellow indicator lamp
flashes
Leakage at the water connection. Internal
leakage, please contact your local Electrolux
Service Force Cen tre.
Indicator lamp for the water
filter flashes.
The filter has been totally utilised. Replace the
filter.
The indicator lamp stays on
and shows yellow
80 % of the filter capacity expended. Buy a
new filter.
Delivery is interrupted after a
short time
The maximum time of two minutes is
attained. Continue with delivery.
If after above checks there is still a fault call your local Service Force Centre.
In-guarantee cu stomers should ensure that the above checks have been made
as the engineer will make a charge if the fault is not a mechanical or electrical
breakdown.
Please n ote that proof of purchase is required for in-guarantee service calls.
TECHNICAL SPECIFICA TION
Model ERES35800W/ERES35800X
Net capacity Refrigerator l 324
Energy consumption kWh/y 175
Dimension mm
Height 1800
Width 595
Depth 650
Perm issible water pressure (to ensure reliable function).
The total flow in the system can vary, depending on local water conditions
and/or water pressure.
Lowest permissible water
pressure. 2,5 bar (250kPa)
Consult your installer if water pressure is
less than 2,5 bar.
Highest permissible water
pressure. 5 bar (500kPa)
If water pressure exceeds 5 bar, than a
reduction valve must be fitted (available
from your specialist shop).
If water pressure exceeds 10 bar, then a
pressure 10 bar (1MPa)