27" Warmer Drawer Specifications
•
Product Weight – 55 Lbs.
•
Voltage Rating –120V/450W/60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 0.45kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
•
Amps @120V = 3.75 Amps
•
Recommended Circuit Breaker – 15 Amps
•
60" electrical cable supplied.
•
Full plywood base required, capable of supporting 100 Lbs.
•
Base must be level and cabinet front must be square.
•
Warmer Drawer can be used alone, or is approved to be used
in combination with any Electrolux Wall Oven. (Refer to Combination
Installation Specifications and drawing on this page.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
27" Warmer Drawer/27" Wall Oven Combination Specifications
•
To support Wall Oven when using in combination with Warmer Drawer,
two 3"-wide x 3/4" thick planks must be installed as a base, capable of
supporting 150 Lbs. Do NOT use full base, since planks are necessary
to allow for proper air displacement.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Warmer Drawer Stand-Alone Installation
23
5
/8"min.
24"max.
4
1
/2" min.
required
distance
to floor
9
7
/8" min.
10
1
/4"max.
25
1
/2" min.
25
3
/4" max.
Full plywood
base required to
support 100 lbs.
Overall depth with drawer fully extended
(includes handle) – 45"
1
3
/4"
23
3
/8"
26
5
/8"
27"
11
1
/4"
Power cord
location (right
center rear)
Two 3" wide
x
3
/4" thick
planks must be
installed, capable
of supporting
150 lbs.
9
7
/8" min.
10
1
/4"max.
1
1
/
2
"
min.
*Critical dimension –
MUST be applied
**Electrical junction
box for Wall Oven
must be lower than
the Warmer Drawer
cutout
†
Maximum height
depends on critical
dimension (
11
5
/
8
")
3"
max.**
Electrical
junction box
location
25
1
/2"min.
25
3
/4"max.
Bottom
of oven
cutout
11
5
/8"
min.*
23
5
/8"min.
24"max.
27
1
/8"min.
4" x 4"
opening
to route
armoured
cable
27
1
/4"
min.
28
5
/8"
max.
1
3
/
4
"
min.
†
27" Warmer Drawer/27" Single