Electrolux EW30IS65JS Range User Manual


 
30" Induction Built-In Range Specifications
Product Weight – 250 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz,
fused on both sides of line with ground. (If local code permits, range may
be connected by hard-wiring or by means of power supply cord kit.)
Connected Load (kW Rating) @ 240/208 Volts = 13.2/9.9 kW
Amps @ 240/208 Volts = 55/48 Amps
Recommended Circuit Breaker – 50 Amps
Always consult local and national electric codes.
Countertop MUST be level in all directions and adjustable range
height at least 1/16" greater than tallest cabinet height, to ensure metal
rangetop flange will fit properly on countertop edge.
When installing optional Backguard Kit, cutout depth of 21-3/4"
minimum / 22-1/8" maximum needs increased to 24".
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than 1/4"
flame-retardant millboard covered with not less than No. 28 MGS sheet
steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. Allow
30" minimum clearance when cabinet is unprotected.
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
When installing range into existing cutout depth greater than 22-1/8",
optional 2" Rear Filler Kit available.
Countertop Preparation
For detailed preparation instructions, refer to installation guide on the web.
Flat square-finish (flat) countertop requires no preparation since rangetop
flange lays directly on countertop edge.
Formed front-edged countertops require front molded edge to be shaved
flat 3/4" from each front corner of opening.
Tile countertops may need cut back 3/4" from each front corner of
opening and/or rounded edge flattened.
For existing cutout width greater than 30-1/16" reduce the 3/4" overlap
dimension or for cutout width of 29", replace actual side trim panels with
smaller side trim panels, available with optional Side Trim Kit (refer to
detailed kit installation instructions).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
2" Rear Filler Kit: S – (PN# 903113-901S).
Side Panel Kit: S – (PN# 903102-901S).
Backguard Kit: S – (PN# 903111-901S).
Side Trim Kit: S – (PN# 903110-901S).
Induction Built-In Range
EW30IS65J S
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxappliances.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
EW30IS65J 01/10 © 2010 Electrolux Home Products, Inc. Printed in the U.S.A.
Overall
depth
including
oven door
in 90°open
position –
45
1
/4"
Power
supply
location
(left
bottom
rear)
28
5
/16"
Side
27
1
/2"
25
3
/4"
Front
30"
31
1
/2"
35
5
/8"
Adjustable
to
36
5
/8"
13
/16"
Front Face of Cabinet
22
7
/8"min.
23
1
/4"max.
1
1
/8"
21
3
/4"min.
22
1
/8"max.
**
Countertop
13"
max.
30"min.
18"
min.
24"min.
1
/2"min.
WALL
31
1
/2"
(critical)
30
±
1
/16"*
Approx.
1
7
/8"
Hatched area
should be flat
and leveled
1
1
/2"
max.
Shave raised
edge to clear
space for
31
1
/2" wide
cooktop rim
30
±
1
/16"*
21
3
/4"min.
22
1
/8"max.
**
1
/2"min.
Locate grounded junction box
or wall outlet 8"-17" from right
cabinet and 2"- 4" from floor
35
3
/4"
min.
36
5
/8"
max.
Locate cabinet
doors 1" min.
from cutout
opening
3
/8"min.
24" min. clearance
with protected cabinet bottom
30" min. for unprotected
*Cabinet and countertop
cutout width should match
**24" with optional
backguard installed