Electrical connections
DANGER
Danger of electric shock! All fittings must be
installed by a competent person in accordance
with current wiring regulations and local
building regulations. If in doubt, consult a
qualified electrician.
IMPORTANT
Always switch off the electricity supply at
the mains during installation, cleaning and
maintenance. We recommend that the fuse is
withdrawn or circuit breaker switched off at the
distribution board while work is in progress.
Step 4:
• Loosenthe2shortscrewsfromthejunctionbox
(g.
)
.
fig.fig.
• Connect the incoming positive, neutral and
ground cables to the respective terminals. The
ground cable is already pre-assembled onto the
junctionboxtoprovidegrounding(g.
).
fig.fig.
L (live) = Black
(ground) =
Green
N (neutral) = White
L
N
• Mount the junction box onto the range hood
using2shortscrews(13)(g.
).
fig.
Step 5:
• Inserttheupperchimney(2)intothelowerchimney
(3)fromtoptobottom(g. ).
• Mountlowerchimney(2)ontherangehood(1).
• Fitthetab,whichisbendby90degrees,intothe
lower bracket notch and mount to the lower bracket
(4)(g. / ).
• Fixitwith2screws(12)(g. ).
fig.
fig.
fig.
fig.
fig.
fig.
• Pulltheupperchimney(2)totheupwardposition
to match the screw hole of the upper bracket.
Mount to the upper bracket (3) with 2 side screws
(10)(g.
).
• Insert2screws(8or11)inthetoplocation,but
donotfullyinsertthescrews(g. ). Mount the
range hood (1) to the wall and tighten the screws.
Insert and tighten the 2 remaining screws on the
bottomlocationoftherangehood(g. / ).
• Attachthecollar(5)totherangehood(1).Secure
with2shortscrews(8)(g. ).
Step 3:
• Mount upper and lower brackets (3, 4) on the
wall. Secure with the remaining 4 sets of long
screws (8). The notches of the lower bracket
shouldbefacinguptowardstheceiling(g.
)
.
• Attachtheexhaustduct.Intheexamplebelow
a round metal duct furnace pipe has been used.
The airtight connection of the exhaust duct
should then be improved with a duct tape. This
ensurestighttandthatnogreasevaporswill
escapefromtheduct(g.
)
.
Installing the hood
Installing the hood
00-Elux FHWC3055LSA-Range-Hood-Book-01.indb 9 12/8/10 12:46 PM