30
Installation
• The electrical outlet should be readily accessible so that the unit can
be unplugged easily in an emergency.
• The socket should not be positioned behind the cupboard.
• The best position is above the cupboard, see (A).
When not connecting the power supply cord to position (A) it should be
removed from the support clip (see diagram, item 13, on page 4) and
routed under the oven.
• Connect the appliance a single phase 230-240V/50Hz alternating current
via a correctly installed earth socket.
The socket must be fused with a ≥10A fuse.
• If the appliance is to be operated in a non-European country, the
supply voltage, current type and frequency of the appliance indicated on the rating plate must
correspond with the specification of your power supply. The rating plate can be found on the inside face
of the control panel.
• The power supply cord may only be replaced by an electrician.
• Before installing, tie a piece of string to the power supply cord to facilitate connection to point (A) when the
appliance is being installed.
• When inserting the appliance into the high-sided cupboard, DONOT crush the power supply cord.
CONNECTING THE APPLIANCE TO THE POWER SUPPLY
ELECTRICAL CONNECTIONS
(A)
• If the plug that is fitted to your appliance is not
suitable for your socket outlet, it must be cut off
and the appropriate plug fitted.
• Remove the fuse from the cut off plug. The cut off
plug should then be disposed of to prevent the
hazard of shocks in case it should be plugged into a
13 Amp socket in another part of your home.
IMPORTANT
The wires in the mains lead are coloured in accordance
with the following code:
GREEN AND YELLOW EARTH
BLUE NEUTRAL
BROWN LIVE
If you fit your own plug, the colours of the wires in the
mains lead of your appliance may not correspond with
the markings identifying the terminals in your plug,
proceed as follows:
• Connect the green and yellow (earth) wire to the
terminal in the plug which is marked with the letter
”E” or the earth symbol ( ) or coloured green and
yellow.
• Connect the blue (neutral) wire to the terminal in
the plug which is marked with the letter ”N” or
coloured black.
• Connect the brown (live) wire to the terminal in the
plug which is marked with the letter ”L” or coloured
red.
WARNING:
THIS APPLIANCE MUST BE EARTHED
The manufacturer declines any liability
should this safety measure not be observed.
13 AMP
GREEN & YELLOW
13 AMP FUSE
BROWN
CORD CLAMP
BLUE
1. AG-21+22D-UK English 20/05/2004 12:30 Page 30