Installation
Wiring to Power Supply
WARNING!
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH
3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE
GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING
WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES
BE CUT OR REMOVED.
Warning: Turn off power circuit at the service panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
16. Remove the knockout and install the conduit connector (1/2") in junction box.
17. Run 3 wires; black, white and green (#16AWG) in 1/2" conduit from service panel
to junction box.
18. Connect black wire from service panel to black or red in junction box, white to
white and green to green-yellow. Figure 6.
19. Close junction box cover. Check all light bulbs to make sure they are secure in
their sockets. Turn power on in service panel. Check lights and blower operation
per Care & Use section of this manual. Install filters.
Final Assembly
20. Install duct cover per Figure 3. Make sure to leave this manual for the home
owner.
21. Make sure to leave this manual for the home owner.
Alternate - reduced ceiling height Installation:
The hood may be installed with only the lower part of the duct cover to reduce the
overall height.
For the duct cover to slide down and engage the top of the hood, the ceiling bracket
must be mounted 1/4" below the ceiling.
The resulting space on top of the chimney can be filled with a 1/4 thick piece of
plywood cut to the inside cross section of the chimney cover and finished to match
the ceiling.
Cut the self-adhesive rubber tape supplied with the hood in 4 identical sections.
Attach two pieces of tape to each side of the ceiling bracket. Figure 7.
Snap lower chimney duct cover into place around ceiling bracket.
Rear discharge:
A 90° elbow may be installed immediately above the hood. For serviceability, a
mounting similar to the straight up discharge shown in Figure 4 should be used.
Figure 6
Figure 7