Electrolux RH30WC55GSB Ventilation Hood User Manual


 
12
Making the electrical connections
Electrical Shock Hazard
Warning: Turn off power at the service panel before
wiring this unit.
120 V AC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN
ELECTRICAL JUNCTION BOX WITH 3 WIRES,
ONE OF WHICH (GREEN/YELLOW) SERVES TO
GROUND THE APPLIANCE. TO PROTECT YOU
AGAINST ELECTRIC SHOCK, THE GREEN AND
YELLOW WIRE MUST BE CONNECTED TO THE
GROUNDING WIRE IN YOUR HOME
ELECTRICAL SYSTEM, AND IT MUST UNDER
NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical
shock.
Remove junction box cover and knockout on the
top left side.
Installing the hood
If not already done, install 1/2” conduit connector
in j-box.
NOTE: This connector is not included with vent
hood.
Run black (live), white (neutral), and green (earth)
wires (#14 AWG) according to the National
Electrical Code or CSA Standards and local
codes and ordinances in 1/2” conduit from power
supply to j-box.
Connect black, white, and green wires from
power supply to black, white, and green/yellow
wires in j-box respectively.
These connections should be done while always
making reference to the electrical diagram found
inside the hood.
Close j-box cover and reapply
Metal electrical
conduit
House
wiring
UL listed
wire nut
Junction box
cover
Knockout