Glass & Stainless Canopy Hood
RH42PC60G S
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
•
250 Bobby Jones Expressway
•
Augusta, GA 30907
•
1-877-4electrolux (1-877-435-3287)
•
electroluxappliances.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
electroluxappliances.ca
RH42PC60G 02/08 © 2008 Electrolux Major Appliances, NA Printed in the U.S.A.
42" Glass & Stainless Canopy Island Hood Specifications
•
Product Weight – 87 Lbs.
•
Island/Peninsula Installation
•
Ventilation is convertible to be either ducted outside, or recirculated
inside requiring no ducting.
•
Sones Rating – 9.0
•
Voltage Rating –120V/60 Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 0.516 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
•
Amps @120 Volts = 4.16 Amps
•
Always consult local and/or national electric codes. Check local
building codes for installation requirements, as they may vary per locale.
•
Minimum installation height allowed from bottom of hood to cooking
surface is 24"- 30" for electric and 30" for gas. (NOT more than 36"
recommended.)
•
To prepare mounting surface, adequate structure and support must be
provided, capable of supporting 150 lbs.
Ducted Option Specifications
•
For outside ventilation only.
•
Exhaust Duct Required – 8" round
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Use metallic flex ducting only to connect rigid duct directly to transitions
(if allowed by code).
•
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
•
Cold weather installations should have additional backdraft damper
installed.
•
Refer to web for detailed duct preparation installation instructions.
Ductless (Recirculated) Option Specifications
•
If ducting to outside is not an option, vent hood can be converted to
ductless with use of optional Duct-Free Kit (RHDFP60GS).
•
Refer to web for detailed convertible ventilation installation instructions.
Pre-Installation Calculations
•
Select hood preference height (P) that is comfortable for user
(24"- 30" minimum allowed, NOT more than 36" recommended).
•
Calculate hood height (H) for installation (H = K-C-P).
•
Confirm that (H) is within minimum to maximum range for hood.
If not, adjust installation.
•
Calculate chimney structure height (S). Use formulas, check
dimensions of hood. Save calculation for use later in installation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
•
Duct-Free Kit – (RHDFP60GS).
Top
Controls
Wiring box
Air outlet -
7
7
/8" diam.
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.
41
7
/8"
25
3
/16"
2
11
/16"
12
1
/8"
13
3
/16"
35"
min.
57"
max.
28"
( min.
height
with one
cover)
K = Kitchen height
C = Counter height
P = Preferred height
of hood bottom
above counter
(24"- 30"
allowed, NOT
more than 36"
recommended)
A = Canopy height
H = Hood height for
installation
H = K-C-P
S = Chimney
structure height
for installation
S = H-A
PRE-INSTALLATION CALCULATIONS
SH
A
K
P
C
Counter Height
36" standard