Electrolux Rm 4211 Refrigerator User Manual


 
5. The ambient temperature is too high.
6. To much food is loaded at one time.
7. The door is not properly closed or the magnetic
sealing strip is defective.
8. More than one source of energy is used at the same
time. If the refrigerator still does not work properly, call
a service technician.
The sealed cooling system must not be
opened, since it is under high pressure.
MAINTENANCE
Concerning gas- and electric installations, only authorized
experts are allowed to carry out maintenance and repair
works. Besides, it is recommendable to contact an
authorized service if it comes to repair works.
According to the valid regulations G607 of DVGW, the
gas installation as well as the connect flue oulets are to
be checked every two years by an expert (this has to be
arranged by the person responsible).
SOME USEFUL HINTS
Make sure that:
The refrigerator is not operating on 12 V when the
vehicle is parked, otherwise you will drain the car
battery in a short time.
Defrosting is carried out periodically.
The refrigerator is left with the door(s) ajar when it
is not to be used for some time.
Liquids or items with a strong odour are well
packaged.
The ventilation openings are unobstructed.
The door is secured by means of the travel catch
when the caravan is on the move.
Only one mode of operation at a time is used to run
the refrigerator.
GUARANTEE AND SERVICE
The refrigerator is guaranteed for one full year on conditi-
on that it is used in a correct manner and in accordance
with these operating and installation instructions.
It is also embraced by a European guarantee as descri-
bed in the brochure supplied with the refrigerator.
Service and spare sparts are obtainable from your dealer
or Electrolux- consult the telephone directory.
TECHNICAL DATA RM 42XX
Overall dimensions, refrigerator
Height 618 mm
Width 486 mm
Depth (incl. cooling unit)
without door 435 mm
with door 474 mm
Build-in dimensions
Height 620 mm
Width 490 mm
Depth 450 mm
Capacity
gross 60 lit.
net 51 lit.
frozen food compt 6 lit.
Weight (without packaging) 21 kg
Electrical data
Input 230 V 105 watt
12 V 100 watt
Energy consumption /24 h 2,3 kWh
LP gas data
Input 186 watt
ditto, low flame 86 watt
Energy consumption /24 h 0,24 kg
Cooling medium Ammonia (R 717)
INSTALLATION INSTRUCTIONS
REPOSITIONING THE HINGES
The door hinges can be moved to the opposite side in the
following way:
Unscrew the upper hinge pin, taking care not to
lose the set of washers and bushes.
Lift the door from the lower hinge pin.
Unscrew the pin and mount it on the opposite side
hinge.
Unscrew the travel catch and mount it on the oppo
site side.
On the upper edge of the door are two plastic
inserts for the alternative holes of the travel catch.
Pry out carefully and exchange.
Fit the door on the pin and reassemble the pin with
washers and bushes in its new place.
Check that the door closes properly and seals all
round.
DOOR PANEL
The door panel can easily be mounted or changed. The
dimensions of the panel must be:
Height 532 mm
Width 453 mm
Thickness max 3,8 mm
Remove the door, see REPOSITIONING THE
HINGES.
Remove the lower trim moulding and then withdraw
the panel by sliding it downwards.
Fit new panel in place and slide it up as far as
possible.
Fit the trim moulding back in place.