Electrolux RM 5405 Refrigerator User Manual


 
V
entilation grilles
T
he openings in the caravan wall must be fitted with the
E
lectrolux Ventilation systems.
F
itting the grilles, model A 1620, fig.2, which were speci-
a
lly developed by Electrolux for this purpose. It is a good
i
dea to install the frame R 1640 (B in fig. 7a) at the same
t
ime. Then the grilles can be easily removed, which permits
i
nspection and small repairs to be carried out without the
n
ecessity for removing the refrigerator from the recess.
I
f there is no outer grille at floor level where leaking gas can
e
scape, a 40 mm hole to the outside should be made in the
f
loor of the recess to drain any unburnt gas to the outside.
F
it the hole with wire mesh and an angled plate to protect
f
rom stones, mud etc.
R
emoval of flue gases
T
he ventilation passage at the rear of the recess, between
t
he outer wall of the vehicle and the refrigerator (fig. 7a/b),
i
s sealed off against the living space, and so cold draughts
a
re excluded (winter camping) and no flue gases can
p
enetrate into the vehicle. Thus a special flue outlet is no
l
onger necessary the gases are dispersed through the
u
pper vent grille.
N
ote: With this mode of installation the same type of grilles
(
without an integrated flue outlet), should be installed at the
u
pper as well as at the lower vent opening. The angled
T
-piece for the flue tube (when delivered) should not be
u
sed in this case.
T
he top of the enclosure above the flue tube (I), fig. 7a/b,
s
hould be covered with aluminum sheet metal, as indicated
i
n (B), to facilitate the heat dispersion.
I
n fig. 7 the letters have the following meaning:
A. Frame R 1640 for the grilles
B. Aluminum cladding
C. Condenser of cooling unit
D. Vent grill A 1620
E. Sealing profile (optional extra)
Width:
525 mm, part. nr. 295 1147-00
486 mm 295 1147-10
F. Refrigerator rear wall
G. Wooden batten 10 x 20 mm (see also fig. 5)
H. Height of the enclosure
(see TECHNICAL DATA)
I. Flue tube
K T-piece ("lazy tee")
L
P GAS CONNECTION
T
he refrigerator is designed for operation on LP gas, the
p
ressure of which must be 28 mbar for Butane and 37 mbar
f
or Propane. Check that this is stated on the data plate.
T
he refrigerator is not designed for operation on town gas
o
r natural gas.
T
he gas installation should only be carried out by an autho-
r
ized gas fitter. It is recommended that the gas pipe feeding
t
he refrigerator is so arranged that it is possible to turn off
t
he supply of the refrigerator. It must be of a type approved
f
or use with continuously operating bottled-gas appliances,
a
nd have threaded compression connections throughout.
P
USH-ON CONNECTIONS MUST NOT BE USED (We do
n
ot approve the use of "rubber" type flexible tubing for
c
onnecting permanently operating appliances of this type in
t
he United Kingdom). All connectors etc. should be of a type
s
pecifically designed for the type and diameter of the con-
n
ection pipe used, and screwed joints should be sealed with
a
joining compound approved for use with bottled gas.
T
he gas supply pipe should be connected to the gas inlet
p
ipe on the right hand side of the gas control valve by
m
eans of a suitable threaded compression coupling.
I
n making the connection to the refrigerator, a gas cock of
a
n approved type for use on LPG must be incorporated in
t
he supply line in a position which is readily accessible to
t
he user. For eventual servicing purposes, the union should
b
e on the outlet side of the cock and the pipework should
b
e positioned so as not to prevent the refrigerator from
b
eing readily withdrawn.
E
LECTRICAL CONNECTION
T
he electrical installation must be carried out in a proper
a
nd durable manner, taking into account all relevant regula-
t
ions and codes of practice. For mains voltage operation, it
i
s important that the circuit to and in the caravan is effec-
t
ively earthed. ALL MAINS VOLTAGE WIRING IN THE
C
ARAVAN MUST BE INSTALLED IN ACCORDANCE
W
ITH CURRENT I.E.E. REGULATIONS INCLUDING THE
U
SE OF AN OUTLET AND COUPLER TO BS4343/-
C
EE17.
F
or connection to a 230 V electricity supply, the refrigerator
h
as a 3-core mains lead which is intended for connection to
a
properly earthed plug and socket outlet. The socket outlet
s
hould be fitted in the caravan in a position readily accessi-
b
le to the user, within reach of the mains lead. In the United
K
ingdom, the plug and socket outlet should be of the non-
r
eversible type.
I
MPORTANT: The wires in the mains lead of this appliance
a
re coloured in accordance with the following code:
G
REEN-AND-YELLOW = EARTH
B
LUE = NEUTRAL
B
ROWN = LIVE
A
s the colours of the wires may not correspond with the
c
oloured markings identifying the terminals in your plug, in
t
he United Kingdom, proceed as follows:
T
he wire which is coloured GREEN-AND-YELLOW must be
c
onnected to the terminal in the plug which is marked with
t
he letter E or by the earth symbol or coloured green or
g
reen-and-yellow.
T
he wire which is coloured BLUE must be connected to the
t
erminal which is marked with the letter N or coloured black.
T
he wire which is coloured BROWN must be connected to
t
he terminal which is marked with the letter L or coloured
r
ed.
11