Installation
818 19 88-01/8 11
The Refrigerator needs Ventilation
Air is fed under the door through the
vent slots in the base and is
exhausted upwards along the back
wall. To ensure proper air circulation
never cover or alter the vent
openings.
Important! If the appliance is
installed under a hanging cabinet, a
clearance of at least 10 cm between
the top of the appliance and the
cabinet above it must be maintained.
Please check whether, after installing
your appliance and especially after reversing the door, the door seal fits
tightly. A badly fitting door seal may lead to heavy frosting and a
higher power consumption (see also "Something not working“).
Appliance Alignment
0 1. The appliance must be level, please compensate for unevenness in the
floor by turning the two adjustable feet at the front.
2. When two appliances are placed beside each other, the spacers
enclosed in the plastic wrapping should be glued between the appli-
ances as shown in the illustration.
.