Electrolux Ventilation Hood Ventilation Hood User Manual


 
13
Unpacking
The fittings supplied to install this cooker
hood can be found with the instruction book
inside the packaging and consists of the
following:
Ducting spigot
Blanking plate
Wall Fitting
The cooker hood is fitted to the wall using the
keyhole slots in the back of the hood.
1. Mark the position on the wall for the two
Ø 8mm dia screw holes (A) as illustrated in the
drawing opposite at 568mm.
2. Check that the hole distances are correct and
are level using a spirit level.
3. At this stage it is important to allow 25mm (1”)
clear space above the cooker hood to enable it
to be hooked onto the screws and for
subsequent removal for decorating or
servicing.
4. Insert the screws and tighten to a distance of
5mm.
Venting
The hood is more effective when used in the
extraction setting (ducted to the outside).
Venting kits may be purchased through your
retailer or DIY store, and must be ducted to
an outside vent of 100mm (4”) minimum.
The ducting used must be manufactured from
fire retardant material which should conform to
the relevant British Standard or DIN4102-B1.
When the hood is ducted externally the
charcoal filter must be removed and the
slider control must be in the ducting position.