Emerson 1F73 Range User Manual


 
www.white-rodgers.com
MOUNTING AND WIRING
CONTINUED FROM PAGE 2
4
L
R
E/W1
24 VAC
120 VAC
Hot
SYSTEM
MONITOR
SWITCH
Neutral
THERMOSTAT
SYSTEM
G W2
Figure 2. Typical wiring diagram for single transformer heat pump systems
TRANSFORMER
(Class II Current Limited)
Changeover
Relay*
CY1
O/B/Y2
Compressor
Contactor
* Changeover Relay is energized in COOL when O/B switch is in the O position
Changeover Relay is energized in HEAT when O/B switch is in the B position
Aux
Relay
(Stage 2)
Fan
Relay
Emergency
Relay
See Note **
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
L
R
E/W1
SYSTEM
MONITOR
SWITCH
G W2
Figure 4. Typical wiring diagram for two transformer heat pump systems with safety circuits in BOTH systems
Changeover
Relay*
CY1
O/B/Y2
Compressor
Contactor
* Changeover Relay is energized in COOL when O/B switch is in the O position
Changeover Relay is energized in HEAT when O/B switch is in the B position
Aux
Relay
(Stage 2)
Fan
Relay
Emergency
Relay
TWO COMMONS MUST
BE JUMPERED TOGETHER!
24 VAC 120 VAC
HOT
NEUTRAL
THERMOSTAT
SYSTEM
HOT
NEUTRAL
120 VAC
Limit or
Safety
Switches
Limit or
Safety
Switches
Limit or
Safety
Switches
24 VAC
Limit or
Safety
Switches
COMMON
COMMON
Auxiliary
Heating
Transformer
(Class II
Current Limited)
Heat Pump Transformer
(Class II Current Limited)
24 VAC
ACCESSORY
RELAY N.O.
CONTACT
Polarity must be observed. If the HOT side of the second transformer
is jumpered to the COMMON side of the first transformer a short will
be made. Damage to equipment will occur when power is restored.
NOTE
The accessory relay scheme
is required when safety
circuits exist in both systems.
NOTE
See Note **
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
L
R
E/W1
24 VAC
120 VAC
Hot
SYSTEM
MONITOR
SWITCH
Neutral
THERMOSTAT
SYSTEM
G W2
Figure 3. Typical wiring diagram for two transformer heat pump systems with NO safety circuits
TRANSFORMER
(Class II Current Limited)
Changeover
Relay*
CY1
O/B/Y2
Compressor
Contactor
* Changeover Relay is energized in COOL when O/B switch is in the O position
Changeover Relay is energized in HEAT when O/B switch is in the B position
Aux
Relay
(Stage 2)
Fan
Relay
Emergency
Relay
Limit or
Safety
Switches
TWO COMMONS MUST
BE JUMPERED TOGETHER!
HOT
NEUTRAL
120 VAC
24 VAC
CUT AND
TAPE OFF!
If safety circuits are in only one of the systems, remove
the transformer of the system with NO safety circuits.
NOTE
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
See Note **