2
EMERSON CONTROL LINK CPC® P/N 818-2050 REFRIG. CONTROLLER: GENERAL PARAMETERS
General Parameters
General parameters are used by techni-
cians and operators to set the control set-
points and defrost schedules.
Before Changing General Parameters
Before changing parameters, clear any
active alarms by pressing the Alarm Si-
lence button.
Changing General Parameters
Do not lightly press buttons! You MUST
use considerable force while pressing
controller buttons or your commands
will not
register!
Press (SET) and hold for five seconds.
If general mode programming has been
password protected, you will see PASS on
the display.
Press (SET) and use the arrow keys to in-
crement the password number until the
correct password is shown and then press
(SET).
Note
: If general parameters an not pass-
word protected, PASS will not appear on
the display.
The display will show the first programmable
parameter: CSP (Case temperature Set Point).
The arrow keys may be used to scroll through
the list of general parameters. To change the
value of any parameter follow these steps:
1. Select the parameter using the arrow keys
(until the code is shown.
2. Press (SET).
3. Current value of this parameter will display.
Use arrow keys to change values.
4. Press (SET) to accept value.
5. Repeat steps 1-4 until all set points have
been properly configured.
6. When finished, press (SET) again for five
seconds to save changes and exit. The
display will blank for one second and then
revert to normal display if the save was
successful.
7. To cancel all changes, press and hold
(SILENCE) for five seconds, or leave con-
troller idle for 60 seconds. You will lose all
setpoint changes made since you entered
General Programming Mode.
See Warning at right.
SFT
Software Version
- - -
WARNIN G !
You MUST press and hold
(SET) after changing setpoints
for changes to be permanent.
Leaving the controller idle for
60 seconds will log you
out and cancel all your
setpoint changes.
Note! See Technical Information Sheet In This Manual For This Case’s Settings
Note! See Technical Information Sheet In
This Manual For This Case’s Settings