Emerson XDCTM Refrigerator User Manual


 
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Liebert Corporation
1050
Dearborn Drive
P.O.
Box 29186
Col
umbus, Ohio 43229
800 877 9222
Phone (U.S. &
Canada Onl
y)
614 888 0246
Phone (Outside U.S.)
614 841 6022
FAX
Via
Leonardo Da Vinci 8
Zona
Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 G
loucester Rd, Wanchai
Hong
Kong
852 25722201 Phone
852 28029250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
Technical Data
Nominal Capacity, 60 Hz 160 kW / 46 Ton
Nominal Capacity, 50 Hz 130 kW / 37 Ton
Input Voltage 460 V, 3 ph, 60 Hz
380/415 V, 3 ph, 50 Hz
Full load amps 79 A
Height 78” (1981 mm)
Width 74” (1879 mm)
Depth 34
5
/8” (879mm)
Weight, empty 1800 lbs (817 kg)
The indoor Li
e
bert Refrigerant Chiller is specifically designed to
support the Liebert XD cooling modules. The XDC connects
directly to the modules through the pumped refrigerant.
When a building chilled water system is available, the Liebert XDP
Pumping Unit is utilized as an interface between the pumped
refrigerant circuit and the chilled water system. Both the XDC
and the XDP units c
irc
ul
a
t
e the refrigerant to the XD modules,
while maintaining the refrigerant at a temperature always above
the ac
t
u
al dewpoint.
Liebert XD Hydraulic System Schematic
While every precaution has been taken to ensure accuracy and
c
om
pl
e
teness in this literature, Liebert Corporation assumes no
r
e
s
ponsib
i
lit
y
, and disclaims all liability for damages resulting
f
rom use of this information or for any errors or omissions.
© 2007 Liebert Corporation. All rights reserved throughout
the w
orld. Specifications subject to change without notice.
All n
ame
s r
e
f
erred to are trademarks or registered trademarks
o
f the
ir r
e
s
pec
ti
v
e o
wners.
® Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-16670 (R12/07) Printed in USA
Business-Critical Continuity, Emerson Network
P
o
wer and the Emerson Network Power logo
are trademarks and service marks of Emerson
Electric Co. ©2007 Emerson Electric Co.
Lie
bert
Hea
t
Rej
ection
Liebert
XDC
Refrigerant
Chiller
Liebert
XDC
Refrigerant
Chiller
Pumped
Refrigerant
Pumped
Refrigerant
XD Cooling Module/Rack
XD Cooling Module/Rack
XD Cooling Module/Rack
XD Cooling Module/Rack
Direct system configuration
Building
Chilled
Water
Liebert
XDP
Liebert
XDP
Pumped
Refrigerant
Pumped
Refrigerant
Indirect system configuration
XD Cooling Module/Rack
XD Cooling Module/Rack
XD Cooling Module/Rack
XD Cooling Module/Rack