STEP 3: PREPARING THE TRANSMITTER
1. Position the remote mount terminal box adjacent to the transmitter and carefully feed the
wire leads so that they are accessible from the electronics access of the transmitter.
2. Place the O-Ring in the groove on the remote mount terminal box.
3. Mount the remote mount terminal box to the transmitter using the bolts provided.
See Figure 3.
4. Connect the wires from the remote mount terminal box to the electronics. Note that the
sockets are different sizes so that they can only be connected one way. See Figure 4.
5. Replace the LOI (if applicable).
6. Replace the electronics side cover.
Figure 3.
Remote mount
terminal box cover
8732/8732_03a.eps
Bolts
Remote mount
terminal box
O-rings
Wiring
Connection