Empire Comfort Systems VFFB-42D Ventilation Hood User Manual


 
R-501010
F
MAINTENANCE.
Keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing area at least
twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer to lighting instructions located on the rating plate of the
log set.
Never obstruct the flow of the combustion and ventilation air. Keep the front of the fireplace clear of all obstacles and
materials.
Leave at least 36” clearance from the front of the fireplace.
Screens should be closed during operation.
E
INSTALLATION OF YOUR VENT-FREE GAS LOG SET.
Any vent-free Gas Log Heater must be “For use with approved ANSI Z21.11.2 Decorative type unvented room heater.”
Follow and complete the installation instructions of the gas log set and the requirements of this fireplace.
Your gas log set can be completely attached to the gas line in the very back of your fireplace at the bulkhead connectors.
A gas shut off must be in this line.
Please check all fittings for leaks before lighting this gas log set.
D-2. INSTALLATION OF OPTIONAL SIMULATED BRICK PANELS.
Remove anything within the fireplace. Install the back panel first and let it rest tight against the back wall. Place one side
panel inside the fireplace and align the brick pattern. The “Z” bracket mounts along the front edge of the side panel and is
held with (2) screws. Repeat the process for the other side panel. (See Fig. 15).
Hold the fan kit upright so the flow from the fan
kit is up the back of the fireplace. Tighten wing
nuts on the screws and tighten completely.
Place speed control into the mounting bracket
located in the right side of this fireplace behind
the bottom grill.
Locate the two legs over the screws coming up
out of the bottom of the fireplace. Attach wing
nuts and tighten completely. Plug into the
junction box on the right side of fireplace.
D-3. OPTIONAL JUNCTION BOX INSTALLATION INSTRUCTIONS FBJB-1
Installation:
1. Installing the FBJB-1, junction box, should be completed during the
installation of the fireplace.
2. Lower door assembly.
3. When facing the front of the appliance, the two screw holes for mounting
the junction box to the interior, right side of the outer casing are adjacent
to the front 1 3/4" diameter access hole.
4. Attach the junction box to the outer casing with (2) two #10 x 1/2" screws
provided.
5. Install wiring to the junction box and install and wire to the plug provided.
6. Attach the cover plate.
Fig. 15. Installation of simulated brick panels.
SIDE
PANEL
Z BRACKET
BACK PANEL
SCREW
SIDE
PANEL