Enviro 50-1235 Ventilation Hood User Manual


 
MANUFACTURED BY:
SHERWOOD INDUSTRIES LTD.
6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3
www.enviro re.biz
April 13, 2005
C-10857
Part Number Option
50-1235
Horizontal Vent Kit
Flue Pipe Adaptor
Wall Framing
Wall Thimble
Fire Stop
Exhaust 4" Flex Pipe
Combusion Air 6 5/8" Flex Pipe
Wire Spacers
Horizontal Vent Termination
9. Install the ex pipe assembly through the wall thimble, ensure that this
portion of pipe slides through the outside wall far enough to connect onto
the vent termination cap.
10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm)
by 5” (12.5 cm) ue collar adaptor previously installed into the replace
ue outlet. Slide the Ø4” (10 cm) ex vent over the ue collar and secure
with three (3) sheet metal screws evenly spaced.
11. Place a bead of high temperature silicone on the intake collar of the
replace, slide the Ø6” (16.25 cm) ex intake liner over the collar,
secure the ex liner with three (3) sheet metal screws evenly spaced.
12. On the outside of the
exterior wall, apply a
bead of Mill-Pac Black
sealant to the Ø 4” (10
cm) pipe of the vent
terminal. Slide the
ex liner onto the vent
terminal and secure with
three (3) sheet metal
screws evenly spaced.
13. Place a bead of high
temperature silicone on
the intake collar of the
vent terminal, slide the
Ø6” (16.25 cm) ex
intake liner over the
collar, secure the ex liner
with three (3) sheet metal
screws evenly spaced.
14. Attach the vent terminal
to the outside of the
house using four (4)
wood screws provided.
15. Light the appliance and
ensure proper operation.
Figure 3
Figure 3