Everpure CGHE1 Water Dispenser User Manual


 
“T” connection with
Shut-Off Valve
EV312120 Installation
shut-off valve
(use EV312120)
“T” connector
TYPICAL INSTALLATIONS
Step 4 - Connect Cold Water Supply
Check Filter in Quick-Connect Fitting
The cone-shaped screen filter comes seated inside the quick-connect fitting with the narrow end pointing
towards the cap which is also attached to the fitting. (The open or wide end of the screen is inserted into
the fitting.) However, the filter may become dislodged in the shipping process. Check to see that it is
seated correctly within the fitting. If the cap is still in place, pop cap off by slipping a screwdriver into the
notch and lift off. Gently pull on the screen. If it comes loose, push in with a light jiggling or wiggling
motion until it snaps into place. If installed properly, a gentle pull should not dislodge it.
Refer to installation instructions included with faucet if necessary.
Cold water is supplied to the tank through the faucet. Connect the cold water line to the faucet using the
1/4” (6.4 mm) supply line and the quick-connect fitting that contains a cone shaped screen filter (supplied
with the tank.) The cap end of the fitting connects to the faucet line.
Make sure the cold water connecting to the faucet is filtered. Use an Everpure Commerical Grade
Filter System to provide filtered water. Refer to the Everpure Filter System Install and Operation
Manual for installation procedures.
It is suggested that a shut-off valve be installed between this connection and the cold water supply line.
Another common installation method is with the use of a saddle valve illustrated below. If a saddle valve
is used, follow the manufacturer’s installation instructions.
faucet line connects to
filtered cold water supply.
clamp
faucet line to
cold water
supply
cold water supply
hose to tank
faucet line
to tank
faucet
quick-connect with filter and cap
quick-connect fitting with filter and cap connects to cold
water line and contains a filter inside fitting. It also has
a cap at one end.
cap
faucet line connects to
the inlet tube located on
top corner of tank with
quick-connect fitting
(supplied with tank).
quick-connect
center inlet tube
filter
hose connects with
clamp to faucet supply
tube at center of tank.