Faber 6074457/630006628 Ventilation Hood User Manual


 
* If you wish to keep the frame of the front panel and only replace the glass panel, the dimensions are as follows:
A=5 11/16”, B=1/8”, C= 23 6/16” (for 24” model) or 29 11/16” (for 30” model) or 35 11/16” (for 36” model). The glass panel is 1/8”
thick, but the frame is adjustable to accommodate a thinner panel like stainless steel.
Rev.06/08
WARNING! Product specifications are subject to change without notification. Consult the installation instructions
before you begin installing this rangehood.
Dimensional Diagram
Make your ductrun as straight and short as possible.
The ductrun should not exceed 25 equivalent feet if
ducted with 3 1/4” by 10” rectangular duct. Count
45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat
elbows as 12 feet.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of 24”
of straight duct between elbows if more than one
is used. Do not install two elbows together. If you
must elbow right away, do it as far away from the
hood’s exhaust opening as possible.
Pre-Planning Your Ductwork - Important:
Consult the installation instructions before you begin
installing this rangehood.
Custom Front Panel Dimensions -
for replacing the entire front panel*
Ductless Installations
For installations where ductwork
is impossible or highly impractical
Charcoal Filters, which attach to
the blower assembly, absorb smoke
and odors.
The blower must be positioned
with the exhaust pointing forward
(so that the exhaust exits from the
front grill).
23 5/8” or 29 15/16” or 35 15/16”
5 7/8”
13/16”
A
B
C
Pre-Planning Your Installation - Important: Consult the installation instructions before you begin installing this
rangehood. The recommended height to install this hood off the cooktop is a minimum of 24” and a maximum of 30” for
maximum effectiveness. Also consult the cooktop manufacturer’s recommendation.