Faber 630000815 Ventilation Hood User Manual


 
upper
chimney
cover
ductless
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
1" min
7" max
31"
36”
x
min & max ceiling height examples
x = 30"
min
8'
4 5/8"
max
8'
10 5/8"
x = 28"
min
8'
2 5/8"
max
8'
8 5/8"
x = 26"
min
8'
5/8"
max
8'
6 5/8"
x = 24"
min
7'
10 5/8"
max
8'
4 5/8"
20"
2
5/8”
3 3/4”
upper
chimney
cover
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
3
3/8”
min
14
3/8”
max
23
5/8”
2
5/8”
36”
x
min & max ceiling height examples
x = 30"
min
7'
11 5/8"
max
8'
10 5/8"
x = 28"
min
7'
9 5/8"
max
8'
8 5/8"
x = 26"
min
7'
7 5/8"
max
8'
6 5/8"
x = 24"
min
7'
5 5/8"
max
8'
4 5/8"
Rev.06/08
WARNING! Product specications are subject to change without notication. Consult the installation instructions
before you begin installing this rangehood.
Pre-Planning Your Ductwork
Ductless Installations*
For installations where ductwork is im-
possible or highly impractical, a ductless
conversion kit is available. A charcoal
lter, which attaches under the blower
assembly, absorbs smoke and odors. A
ductless diverter assembly directs the air
out to a lower chimney with a vent grate
cut into the back.
Make your ductrun as straight and short as possible. The ductrun should
not exceed 35 equivalent feet if ducted with the required minimum of 6”
round duct. Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º at
elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that
there is a minimum of 24” of straight duct between elbows if more
than one is used. Do not install two elbows together. If you must
elbow right away, do it as far away from the hood’s exhaust opening
as possible.
Ducted
* it is highly recommended that professional style cooking always be vented to the outside.
Ductless
Dimensional Diagrams
Pre-Planning Your Installation -
Important: Consult the installation instructions before you begin installing this rangehood.
Note: The Ductless
Vent Grate exhausts
toward the rear of the
chimney.
Ducted Ductless
The ducted Axia Isola chimney can be adjusted for ceilings between 7’ 5 5/ 8” and 8’ 10 5/ 8” depending on the distance between the bottom of the hood and the
cooktop (distance x in above DUCTED diagram). The ductless Axia Isola chimney can be adjusted for ceilings between 7’ 10 5/ 8” and 8’ 10 5/ 8” depending on the
distance between the bottom of the hood and the cooktop (distance x in above DUCTLESS diagram).