Faber Diamante Ventilation Hood User Manual


 
Version 12/04 - Page 8
FOR DUCTLESS INSTALLATIONS
Ductless installations require a Ductless Conversion Kit
whose components are pictured in FIGURE 8. Do not use
the DAMPER (H in FIGURE 1) for ductless installations.
The LOWER CHIMNEY COVER (B in FIGURE 1) should
be discarded and replaced by a new one with holes (1 in
FIGURE 8).
1. As indicated in FIGURE 8, fit the DUCTLESS DIVERTER
(5) over the duct outlet. Fit the 2 DIVERTER EXTENSION
HORIZONTAL pieces
(4) on either side of the DUCTLESS
DIVERTER.
2. Install the CHARCOAL FILTER (6) behind the center grease
filter opening by inserting and locking into place, as indicated
in FIGURE 9.
1. LOWER CHIMNEY DUCTLESS
2. LEFT VENT GRID
3. RIGHT VENT GRID
4. DIVERTER EXTENSION HORIZONTAL (2 PIECES)
5. DUCTLESS DIVERTER
6. CHARCOAL FILTER
FOR ALL INSTALLATIONS
1. Remove the cover from the Field Wiring Compartment with a phil-
lips screwdriver. Feed the Power Supply Cable through the electrical
knockout. Connect the Power Supply Cable to the rangehood cable.
Attach the White lead of the power supply to the White lead of the
rangehood with a twist-on type wire connector. Attach the Black lead
of the power supply to the Black lead of the rangehood with a twist-
on type wire connector. Attach the Power Supply Cable grounding
lead to the green screw provided. Using the 4 holes provided screw
the Field Wiring Compartment to the wall as dictated by your Power
Supply Cable location (screws not provided). Replace the cover.
2. Install the UPPER CHIMNEY COVER (C in FIGURE 10) by slightly
widening the two sides and hooking them behind the CHIMNEY
MOUNTING BRACKETS (E). Secure the sides to the CHIMNEY
MOUNTING BRACKETS with the 4 CHIMNEY SCREWS (G)
.
3. Install the LOWER CHIMNEY COVER (B) by slightly widening
the two sides of the LOWER CHIMNEY COVER and hooking them
between the UPPER CHIMNEY COVER and the wall making sure
that it fits snugly. Secure the LOWER CHIMNEY COVER to the
CANOPY SECTION (A) with 2 CHIMNEY SCREWS (G)
.
FIGURE 10
FIGURE 8
FOR DUCTLESS
INSTALLATIONS
Fit the LEFT AND RIGHT
VENT GRIDS (2 and 3)
into the LOWER CHIMNEY
DUCTLESS holes, making
sure that the directional
symbols are towards the top
and front of the hood and that
they connect snugly to the
DIVERTER EXTENSION
HORIZONTAL pieces.
FIGURE 9
FIGURE 11