Faber Diamante Isola Ventilation Hood User Manual


 
Version 08/06 - Page 4
TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE
High Ceiling Chimney Kit
Extends the island chimney for high
ceilings
part # 620000558 - Stainless
*Ductless Conversion Kit
For non-vented installations only
* it is highly recommended that professional
style cooking always be vented to the
outside
part # 620000557 - Stainless
Replacement Charcoal Filter
For non-vented installations only,
replace charcoal filter as needed
part # 620000041
UNPACK THE RANGEHOOD
Remove the rangehood from the carton and place on a flat surface for assembly. Before discarding the packaging, check to
make sure that no mounting hardware or parts are missing. DO NOT REMOVE THE PLASTIC COVERING ON THE CHIMNEYS
AT THIS TIME! This plastic covering protects the chimney from scratches during installation.
For safe packaging, the entire chimney section of the hood is shipped assembled. It must be disassembled completely for
installation. Disassemble packaged chimney components by sliding apart the chimney covers (B and C in FIGURE 1). Remove
the LOWER CHIMNEY COVER (B) from the CHIMNEY SUPPORT (D) by removing the 2 philips screws on the outside bottom
of the chimney cover. Remove the UPPER CHIMNEY COVER (C) from the CHIMNEY SUPPORT (D) by removing the 2 philips
screws on the outside top of the chimney cover.
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 35 equivalent
feet if ducted with the required minimum of
6" round duct. Calculate the length of the
ductwork by adding the equivalent feet in
FIGURE 2 for each piece of duct in the system.
An example is given in FIGURE 3.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum
of 24" of straight duct between elbows if
more than one is used. Do not install two
elbows together. If you must elbow right
away, do it as far away from the hood's
exhaust opening as possible.
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
FIGURE 3
3.0 feet
5.0 feet
12.0 feet
0.0 feet
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 2
9.0 feet
10.0 feet
0.0 feet
19.0 feet
PREPARING TO ATTACH THE CHIMNEY
The rangehood attaches to the ceiling by a
metal support structure (D in FIGURE 1). This
support must be attached to the ceiling before
the canopy is attached. This structure must
be firmly attached to the ceiling.
FOR WOOD CEILINGS: Use four 4" long
wood screws and washers.
FOR PLASTER OR SHEET ROCK CEILINGS:
If possible, the support must be attached to
the ceiling joists. If not, a supporting structure
behind the sheet rock must be built.
FOR WOOD SHELVES: Use items F, H, &
I in FIGURE 1.
FIGURE 1
RANGEHOOD COMPONENTS
A. CANOPY SECTION
B. LOWER CHIMNEY COVER
C. UPPER CHIMNEY COVER
D. CHIMNEY SUPPORT
E. CANOPY SCREWS
F. WOOD SHELF BOLTS
G. PLUGS - DO NOT USE
H. WOOD SHELF WASHERS
I. WOOD SHELF NUTS
J. MOUNTING TEMPLATE
K. CONNECTOR BOX HALVES
L. CONNECTOR BOX SCREWS
M. CONNECTOR BOX SCREWS
N. DAMPER
O. EASY CUBE™